![MHM iQ-Oval CDS Скачать руководство пользователя страница 61](http://html1.mh-extra.com/html/mhm/iq-oval-cds/iq-oval-cds_operating-instructions-manual_1783429061.webp)
Operating instructions iQ-Oval CDS V1-4.docx
page 61 of 66
9.9.1.
Error Messages control system
The following error messages can be displayed on the tablet or terminal:
Error-
code
Error message
Error reasons / actions
#0001
Quick-Stop
Safety circuit was interrupted.
•
Emergency stop button was pressed.
•
“Control ON/OFF” is on off position.
#0002
Low Pressure
Failure signal from main air pressure sensor.
•
Air supply is not connected.
•
Wrong pressure adjusted.
•
Air supply pressure is too low.
#1001
on Tablet:
"Error & Check Station"
on Terminal:
„
warning
icon + station number
“
Error station. Ready signal from dryer is
missing. Error number can be seen at the
station display.
#1002
on Tablet:
"Error & Check Station"
on Terminal: „warning
icon + station number“
Error station. End position not reached, sensor
signal is missing. Error number can be seen at
the station display.
#1003
on Tablet:
"Error & Check Station"
on
Terminal: „warning
icon + station number“
Error station. Squeegee carriage didn
’t left start
position. Error number can be seen at the
station display.
#2001
CAN-Bus: Missing Station Error in station programming. One station is
missing.
#2002
CAN-Bus: Missing
Terminal
Terminal not found.
#2003
CAN-Bus: Station behind
Terminal
Error station configuration.
Bus address of station is bigger than bus
address of terminal.
#2004
CAN-Bus: Slave Terminal
Missing
Only at 2-Job-Mode. The second terminal
couldn’t be found.
#7000
Functionality not
Supported
Wrong firmware on master PCB
#7001
Incompatible Hardware
found
Update not possible because of wrong
hardware
#7002
Functionality not
Supported
Wrong software version on PCB
#7003
Different Software-
Versions
Different software versions on PCBs