9.1.1.
Putting the Machine into Operation
To put the machine into operation the following switches must be at ON-Position:
•
Main power switch
The Main power switch connects or disconnects the supply voltage to the
machine.
•
Control ON/OFF
“Control ON/OFF” is used to switch the control power supply which suppli
es all
control components inclusive the tablet.
•
Main switch tablet
Push “Main switch tablet” shortly to start the tablet. When the tablet was in idle
state before, starting takes only a few seconds. When tablet was switched off,
starting takes up to one minute. When desktop is displayed tap on the MHM
icon to start control software.
After starting up the tablet a reference drive must be made. Start with button “Start
Reference Drive” when displayed. The tables start to move automatically. It is possible
to
interrupt a reference drive with button “Skip Ref.Drive”
(in this case automatic index
movement is not possible). When all tables are on position they will be locked
automatically.