![MHM iQ-Oval CDS Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/mhm/iq-oval-cds/iq-oval-cds_operating-instructions-manual_1783429022.webp)
Operating instructions iQ-Oval CDS V1-4.docx
page 22 of 66
Power supply tablet To load the battery of the tablet the power supply must be
connected. To prevent battery from discharging, pr
ess “Main
switch tablet” shortly to put tablet into idle mode. If this is not
done, the tablet must be restarted the next day.
7.4.
Safety Devices
The safety devices serve as emergency stop facilities to avoid accidents and to
guarantee safe operation of the machine. The iQ-Oval CDS has the following safety
devices:
Safety device
Description
EMERGENCY STOP
(push button)
Push buttons located at the main control panel and on each
print station. In case of emergency, pressing an emergency
stop button will stop all movements of the machine. The
function of the push button is cancelled by turning it to the
right or pulling the switch up.
Safety bars
Safety bars located at the right and the left of the
‘load/unload’ area. Pressing any one of these bars will result
in an immediate EMERGENCY STOP of the machine. The
location of these bars ensures that the EMERGENCY STOP
function is activated automatically should a person become
trapped between print station and pallet.
Safety cable
The safety cable blocks the danger zone between two print
stations. When the cable is disconnected, an immediate
EMERGENCY STOP is activated.
7.5.
Base frame
All components except the control panel are mounted to the base frame.
7.6.
Tables
The tables move around the base frame. The pallets are mounted on the tables.
Through a pneumatic locking system, it is possible to change the pallets semi-
automatically.
These safety devices must not be used to switch off the machine
under normal operation. Any EMERGENCY STOP presents an
exceptional loading to the machine. Excessive use will result in
damage to the machine along with subsequent cancellation of the
warranty.