![MHM iQ-Oval CDS Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/mhm/iq-oval-cds/iq-oval-cds_operating-instructions-manual_1783429037.webp)
Operating instructions iQ-Oval CDS V1-4.docx
page 37 of 66
9.1.2.
Switching the Machine Off after normal operation
The following order of operations must be observed when switching off the iQ-Oval CDS
after normal operation:
▪
Clean all print stations.
▪
Press “Main switch tablet” shortly to put tablet into idle mode. This is necessary
to prevent battery from discharging. If this is not done, the tablet must be
restarted the next day. The handling is similar to modern Smartphones.
▪
Switch off control power supply with “Control ON/OFF”
-Switch. By doing this
energy can be saved.
▪
Switch off the iQ-Oval CDS with the main power switch. This will disconnect the
main power supply completely, no energy will be consumed.
9.1.3.
Stopping the Machine in the event of an Emergency
If the operator detects any danger to personnel or the iQ-Oval CDS, he can immediately
shut down the machine by pressing one of the
EMERGENCY STOP
push buttons, one
of the
SAFETY BARS
or disconnecting a
SAFETY CABLE
.
There are
EMERGENCY STOP
push buttons located on the control
panel and the print stations. The operating staff must be aware of its
location in order to stop the machine in the event of an emergency
as quickly as possible.
When having dangerous electrical problems the main power switch
must be used to disconnect the machine from the main supply
voltage immediately.
These safety devices must not be used to switch off the machine
under normal operation. Any EMERGENCY STOP presents an
exceptional loading to the servo-motor and transmission etc.
Excessive use will result in damage to the machine along with
subsequent cancellation of the warranty.