The main control panel includes the following features:
Machine feature
Description
Control panel
The control panel is used to control the machine and to
assign the required parameters of the iQ-Oval CDS
’s control
program. Tapping on the command buttons will operate
various individual functions of the machine. You will find a
detailed description of al
l functions in section “
.
Reset button
To cancel a safety device shutdown first press the ERROR
RESET PUSH BUTTON and clear error message on tablet
afterwards.
Control ON/OFF
“Control ON/OFF” is used to switch the control power supply
which supplies all control components inclusive the tablet. To
switch off the main power use the main power switch.
Safety level key
In operating mode ADJUST an automatic error resetting can
be activated; this is needed for adjusting the machine. This
can be done by switching the safety level key to 1-position, in
normal operation the key must be on 0-position. Only
properly trained and suitably qualified personnel should use
this function. The quick stop function of the turn table is
active all the time. Print and Flood strokes can also be made
at active error situations. Active error resetting is displayed
with the safety level signal lamp.
Tablet
m-touch pro
The tablet PC is used to control the main operating features
of the Synchroprint. Touching (tapping) the command
buttons displayed on the screen will operate various
individual functions of the machine. You will find a detailed
description of all functions in section “
.
Main switch tablet
Use “Main switch tablet” to switch the tablet on, off or to put
it into idle state. When the unit is on, push shortly to change
into idle state. After a longer push a menu will be displayed
where the unit can be switched off completely. To start the
tablet a short push is enough. The handling is similar to
modern Smartphones.
EMERGENCY STOP
(push button)
The EMERGENCY STOP push button is part of the safety
facility. See section. 7.4. Safety Devices
Skip button
Press the Skip-Button when substrate is not applied in a
correct way. In this case the respective print station will not
start to work and the substrate will not be printed. The print
process at other stations and pallets will not be interrupted.