5.3.
Ambient Conditions
For the electrical equipment on the iQ-Oval CDS, ambient conditions according to
standard IEC 60204 “Electrical Equipment of Industrial Machines” should be observed.
The following points should be observed in order to achieve efficient running and an
optimum level of production with the iQ-Oval CDS:
1.
The premises, where the iQ-Oval CDS is to be operated, must be kept clean, dry
and well-aired.
2.
The ambient temperature must not fall below +5° C or 45° C.
3.
Relative air humidity must not exceed 80 %.
4.
The mains supply must not exceed or fall below a tolerance of +/- 5 % of the
required voltage for the iQ-Oval CDS. If this voltage stability cannot be
guaranteed, the customer must install a constant-voltage regulator to protect the
iQ-Oval CDS against such fluctuations.
5.
The compressed air must be clean, filtered and dry (class 1:4:1 according
ISO8573-1:2010).
6.
Compressed air supply must be sufficient in terms of pressure, volume and
consistency.
7.
Electricity supply should be sufficient with adequate fuse protection.
8.
Maximum installation altitude is 2000m above sea level.
5.4.
External supply/Connection ports
Connections for compressed air and mains electricity are located on the base unit of
the iQ-Oval CDS as standard. Overhead supply connections may be ordered optionally
but only at time of order, to enable supplies to enter the machine from above.
Danger of tripping over!
In case of laying supply lines on the floor, it is necessary to attach
step covers.