![MHM iQ-Oval CDS Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/mhm/iq-oval-cds/iq-oval-cds_operating-instructions-manual_1783429044.webp)
Operating instructions iQ-Oval CDS V1-4.docx
page 44 of 66
9.4.3.
Automatic
In Automatic-mode index and working cycles start continuously.
The following buttons are displayed:
Button
Functional description
Is used for the sequential start of a new print job/run. It
activates each selected print station/flash cure unit in
sequence when commencing a production run. After the
first complete printing cycle with all enabled print
stations/flash cure units, the startup mode will be turned
off automatically.
Is used to switch off the print stations one by one when
print job is finished.
Starts a sample print. The desired amount can be
increased by pressing the button “Sample” more often.
The actual adjusted amount is displayed at “Produce”.
The sample will automatically perform the required inlet
and outlet mode, the manual adjustment is not
necessary.
Warming up the pallets to working temperature. For this
only active drying stations are used. Warming up is
necessary to get the same print results from the
beginning.