Dual Electric Variable Speed Controller
Dual Electric Variable Speed Controller allows each electric motor to be independently controlled. Controller consists
of the following functions: on/off, dual variable speed control, and a blast feature.
OPERATION
When controller ON/OFF switch is in the OFF position, the
controller has no functions and spreader will not operate. When ON/OFF
switch is in the ON position, the controller functions are able to be used and
spreader can operated. When controller is on green LED lights will illuminate
over variable speed dials.
AUTO-BLAST FEATURE
Each time the controller is turned on, the auto-blast
feature will start automatically. The auto-blast feature will automatically increase
the speed of both electric motors to setting
for three seconds. After three
seconds the electric motor speeds will return to the speed as set on the dials.
The auto-blast feature is intended to clear any material jams that may have
occurred when transporting the spreader.
VARIABLE SPEED SETTINGS
Controller is equipped with dual variable
speed dials, one each for the conveyor and spinner electric motors. Variable
speed dials have setting of with setting being full speed. NOT
depending upon the weight of material on the conveyor or spinner, electric
motors may not operate at lower dial settings.
BLAST FEATURE
Controller is also equipped with a blast feature. The blast
feature allows for momentary high output spreading. When the AST button
is depressed, yellow LED will illuminate and conveyor and spinner speeds will
automatically increase to setting
, when AST button is released, conveyor
and spinner will return to speed set on variable speed dials.
JAM / OVERLOAD MODE
Controller is equipped with a jam and overload
feature. When amperage required by electric motors exceeds the safe level the
controller will enter the overload function. The overload function will reduce the
amperage to a safe level. Overload mode can be identified by the illumination
of the red ashing D marked O R OAD. If overload function is unable to
clear obstruction, controller will enter the jam mode which will be indicated by
the illumination of the red D marked AM. When controller enters the am
mode, all functions of the controller will stop to protect electrical system from
damage. Once the obstruction is cleared the controller will need to be switched
off and then back on to clear jam mode before operation can resume.
Mounting Bracket
Yellow LED
Red LED Overload Red LED Jam
Blast
On/OFF
Conveyor Speed Adjustment
Spinner
Speed Adjustment
Green LED
Green LED
Wireless Electric Variable Speed Controller
The wireless electric variable speed controller is intended to control the speed of a single electric motor. Controller
system consists of a transmitter and receiver. The receiver is mounted on the spreader near the electric motor. The
transmitter is intended to remain in the vehicle cab or with the operator.
OPERATION
Controller is not functional until turned
on by pressing the ON button on the transmitter. Once
controller is turned on then the operator can select any of
the five available speeds.
The controller blast feature is intended to override the
current speed setting and operate the motor at full speed
until deactivated. Blast feature can be deactivated at any-
time and controller will return to previous speed setting.
y pressing the OFF button on the transmitter, controller
and motor are both turned off and will not operate.
1.
ress ON button to activate controller.
2.
Press desired speed selection button.
3.
The conveyor speed can be increased or
decreased at anytime by pressing the appropriate
speed selection button.
4.
ress the
AST button to activate the blast
mode, press the
AST button a second
time to deactivate the blast mode.
5.
ress the OFF button to stop spreader and shut
off the controller.
BUTTON FUNCTIONS
1.
ON
2.
1/5 SPEED
3.
2/5 SPEED
4.
3/5 SPEED
5.
4/5 SPEED
6.
5/5 SPEED
7.
AST
8.
OFF
7
–––––––
5
–––––––
3
–––––––
1
–––––––
–––––––
8
–––––––
6
–––––––
4
–––––––
2
SPECIFICATIONS
olt
Fre uency
MHz S /
MHz urope
Transmitter battery CR
ithium utton Cell
Transmitter
Receiver
Содержание LPV 3
Страница 14: ...14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 LPV Component Identification GASOLINE ENGINE...
Страница 16: ...16 ELECTRIC LPV Component Identification 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15...
Страница 18: ...18 PV Spreader Component Identification 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 GASOLINE ENGINE...
Страница 20: ...20 PV Spreader Component Identification ELECTRIC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18...
Страница 22: ...22 PV Spreader Component Identification HYDRAULIC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19...
Страница 24: ...24 GAS ENGINE Polyhawk Component Identification 1 2 3 4 5 6 8 9 10 11 12 13 14 15 16 17 18 19 7...
Страница 26: ...26 ELECTRIC Polyhawk Component Identification 1 2 3 4 5 6 8 9 10 11 12 7 13 14 15 16 17 18 19...
Страница 28: ...28 1 2 3 4 5 6 8 9 10 11 12 HYDRAULIC Polyhawk Component Identification 7 13 14 15 16 17 18 19 20...
Страница 53: ...53 Operating Instructions Left Right Pattern Left Spread Pattern Right Spread Pattern WindRow Spread Pattern...
Страница 71: ...71 Notes...
Страница 72: ...72...