81 - 81 021537/06/10
registers PR and PT’.
A value of SM > 0 delays the boot procedure for approx. 200 ms. This should be taken
into consideration when using ‘Fastboot’., see
Value range 0..255
Initial value 0
Command SP
<id>SP<para5> Store parameter data set
Access User mode
Description A data set can be stored by this command. All parameters are stored internally and can
be reloaded by RP, see
Command RP
. The data set with index ‘0’ contains the
parameters on delivery and cannot be overwritten.
The data sets ‘1’ and ‘2’ are available for use.
Value range 0..2
Command SS
<id>SS<para5> System status (System Status)
Access: Enquiry mode
Description: Outputs the selected parameters of all commands. All parameters stored in the
EEPROM are output here.
Before parameters of the ULTRASONIC are changed, this command should be used to
generate and save a list of the selected parameters, e.g. by copying parameters to a
text file.
Parameter description:
No parameter is necessary when using the command SS. Callup with selected
instrument - ID 00 is as follows:
00SS<cr> with <cr> Carriage return (Enter key)
Range of values No value range
Initial value: No initial value
Command SV
<id>SV<para5> Software version (Software Version)
Access: Enquiry mode
Description: This command reads out the current software version and gives it back. For
interpretation the version output must be divided by 100. The output value 00SV00123
represents version V1.23.
'1' means the main version, 23 is the build label. The build label is changed when
available functions have been changed. The version changes when new functions have
been added.