32 - 32 021537/06/10
00AC16 (Activate burst mode)
Burst mode configuration with maximum measuring speed, with plausibility check, analog
measured value and user-specific output telegram
00KY1
00DM0 (Switch to half duplex mode. ATTENTION!! Adapt wiring of
RS485!!!)
00KY1
00AB1 (Activate analogue input)
00TB6 (Data output after measurement: User-specific output telegram)
00UT@12,6,2@,@13,6,2@,@63,5,0@,@7,9,0@\0d
(Configuration of user-specific telegram with
Wind speed, Wind direction, analogue measuring value,
time stamp)
00US2 (Storage of user-specific telegram)
00AU1 (Update of analog inputs to maximum speed (max. 3ms))
00BS100 (100 measurements in burst mode)
00BP100 Recording of data 100ms before the trigger event
00MD0 (No delay between measurements)
00MA0 (Switch-off of automatic measuring speed adjustment)
00PC7 (Switch-on of plausibility)
00AC16 (Activate burst mode)
Ending burst mode
•
End burst mode with command 00AC0
•
Activate required output telegram with command TT
Restrictions in burst mode
Measurement in burst mode is subject to the following restrictions:
•
No standard deviations and covariance’s are calculated in burst mode
•
The mean value buffer is deleted after burst mode
•
Burst mode does not function in bus mode
•
When using the analog input, the first two analog measured values may contain
incorrect values depending on the setting. Such behaviour is due to technical
reasons and cannot be prevented.
•
In the period of the pre-trigger the recorded analogue values are invalid.