
FOCKE MELER GLUING SOLUTIONS, S.A.
4-28
MELTER OPERATION
Programming speed ramp
To access this menu and program the different points corresponding to the
voltage-speed ratio, you must select external reference (‘ref ext’ LED is
illuminated) and press the right arrow key. Then the following message is
displayed:
The IN LED to the position
ON
and the OUT LED to the position
OFF, 1 000,
NOT EDITABLE;
press the right arrow to go to the next point:
The IN LED to the position
OFF
and the OUT LED to the position
ON, 1 XXX,
which means that the output speed is being programmed for point 1 (when the
input voltage is 0 V); with the up/down arrow keys the value may be modified,
within a range from 000 to MAXIMUM RPM; press the right arrow key to go to
the next point:
The IN LED to the position
ON
and the OUT LED to the position
OFF, 2 XXX
,
which means that the input voltage value is being programmed for point 2;
with the up/down arrow keys the value may be modified, within a range from
00.0 to 10.0 (to one decimal place); press the right arrow key to go to the next
point:
The IN LED to the position
OFF
and the OUT LED to the position
ON, 2 XXX,
which means that the output speed value is being programmed for point 2;
with the up/down arrow keys the value may be modified, within a range from
000 to MAXIMUM RPM; press the right arrow key to go to the next point:
The IN LED to the position
ON
and the OUT LED to the position
OFF, 3 XXX
,
which means that the input voltage value is being programmed for point 3;
with the up/down arrow keys the value may be modified, within a range from
00.0 to 10.0 (to one decimal place); press the right arrow key to go to the next
point:
The IN LED to the position
OFF
and the OUT LED to the position
ON, 3 XXX,
which means that the output speed value is being programmed for point 3;
with the up/down arrow keys the value may be modified, within a range from
000 to MAXIMUM RPM; press the right arrow key to go to the next point:
The IN LED to the position
ON
and the OUT LED to the position
OFF, 4 XXX,
which means that the input voltage value is being programmed for point 4;
with the up/down arrow keys the value may be modified, within a range from
00.0 to 10.0 (to one decimal place); press the right arrow key to go to the next
point:
The IN LED to the position
OFF
and the OUT LED to the position
ON, 4 XXX,
which means that the output speed value is being programmed for point 4;
with the up/down arrow keys the value may be modified, within a range from
000 to MAXIMUM RPM; press the right arrow key to go to the next point:
The IN LED to the position
ON
and the OUT LED to the position
OFF, 5 100,
NOT EDITABLE; press the right arrow key to go to the following message:
The IN LED to the position
OFF
and the OUT LED to the position
ON, 5 XXX,
which means that the speed value is being programmed for point 5; with the
up/down arrow keys the value may be modified, within a range from 000 to
MAXIMUM RPM; press the right arrow key to exit the menu.
Press the right arrow key to return to the menu, and the initial message is
displayed: The IN LED to the position
ON
and the OUT LED to the position
ON,
1 000.
To exit this menu, the equipment must be turned off and started up using the
control card ON/OFF button.
To save the newly entered data, use the right and left arrow keys to go forward
or backward in the menu: if any field has been modified using the up/down
arrow keys, and the ON/ OFF button is pressed to turn the equipment off, the
data will not be saved.
Содержание PS200
Страница 1: ...MA 5066 ENG 250220 GLUING SOLUTIONS ADHESIVE MELTER PS200 DRUM UNLOADER INSTRUCTIONS MANUAL ...
Страница 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 34: ...FOCKE MELER GLUING SOLUTIONS S A 3 12 INSTALLATION This page is intentionally left blank ...
Страница 68: ...FOCKE MELER GLUING SOLUTIONS S A 4 34 MELTER OPERATION ...
Страница 75: ...ELECTRICAL DRAWINGS 7 1 MA 5066 ENG PS200 DRUM MELTER MANUAL 7 ELECTRICAL DRAWINGS ...
Страница 76: ...FOCKE MELER GLUING SOLUTIONS S A 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 78: ...FOCKE MELER GLUING SOLUTIONS S A 8 2 PNEUMATIC DIAGRAMS 1 2 3 4 5 6 9 8 7 11 12 10 13 14 ...
Страница 80: ...FOCKE MELER GLUING SOLUTIONS S A 8 4 PNEUMATIC DIAGRAMS This page is intentionally left blank ...
Страница 82: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST A STRUCTURE 7 5 4 6 2 3 9 8 1 ...
Страница 84: ...FOCKE MELER GLUING SOLUTIONS 9 4 SPARE PARTS LIST B PLATEN ENSEMBLE 2 3 4 5 7 8 6 1 ...
Страница 86: ...FOCKE MELER GLUING SOLUTIONS 9 6 SPARE PARTS LIST C SIMPLE MANIFOLD ENSEMBLE 7 5 13 14 9 10 11 12 3 4 2 1 6 8 ...
Страница 88: ...FOCKE MELER GLUING SOLUTIONS 9 8 SPARE PARTS LIST C DOUBLE MANIFOLD ENSEMBLE 4 12 2 3 6 5 8 7 9 10 11 1 ...
Страница 98: ...FOCKE MELER GLUING SOLUTIONS 9 18 SPARE PARTS LIST This page is intentionally left blank ...