MELTER OPERATION
4. Press the button with the clock symbol once again.
The status will alternate each time you press the button.
5. Pressing either the left or the right arrow button will exit this program
and return to the platen temperature display.
Special function buttons
The simplicity of programming PS200 drum melters reduces the use of the
special function buttons to only the standby function.
This manual function allows you to alternate between the operational mode
and the standby mode. Using the standby function during periods of melter
inactivity helps save energy and allows the heated elements to return quickly
to their set point temperatures once you return to the operational mode.
When the standby function is activated, the set point temperature for all
the heated components is lowered to a certain value, according to the
programmed parameter (see ‘Programming melter equipment parameters’).
For example, if the platen set point temperature is 160 °C and the standby
temperature is programmed as 30 (30%), when you press the standby function
button, the platen set point temperature will drop to 112 °C (70% of 160 °C).
The three means for activating the standby function available with PS200
melters have the following priority protocols:
1. Manual standby function button.
2. Standby function external signal.
3. Standby function activation/deactivation programming.
Therefore, if the function is activated by any of the three means, it may always
be deactivated using the manual button. On the other hand, if it was activated
using the manual button, it may not be deactivated by either of the other two
means. The weekly programming may not deactivate a standby function that
has been activated by either of other two means.
The following criteria are suggested for standby function use:
- If the period of inactivity is less than 2 hours, allow the melter
applicator equipment to heat as normal.
- If the period of inactivity is more than 2 hours and less than 4 hours,
use the standby function.
- If the period of inactivity is over 4 hours, use one of the following two
options: turn off the equipment if you do not plan on using it for the
rest of the day or keep the standby function on if you plan on using the
equipment during that same day.
Содержание PS200
Страница 1: ...MA 5066 ENG 250220 GLUING SOLUTIONS ADHESIVE MELTER PS200 DRUM UNLOADER INSTRUCTIONS MANUAL ...
Страница 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 34: ...FOCKE MELER GLUING SOLUTIONS S A 3 12 INSTALLATION This page is intentionally left blank ...
Страница 68: ...FOCKE MELER GLUING SOLUTIONS S A 4 34 MELTER OPERATION ...
Страница 75: ...ELECTRICAL DRAWINGS 7 1 MA 5066 ENG PS200 DRUM MELTER MANUAL 7 ELECTRICAL DRAWINGS ...
Страница 76: ...FOCKE MELER GLUING SOLUTIONS S A 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 78: ...FOCKE MELER GLUING SOLUTIONS S A 8 2 PNEUMATIC DIAGRAMS 1 2 3 4 5 6 9 8 7 11 12 10 13 14 ...
Страница 80: ...FOCKE MELER GLUING SOLUTIONS S A 8 4 PNEUMATIC DIAGRAMS This page is intentionally left blank ...
Страница 82: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST A STRUCTURE 7 5 4 6 2 3 9 8 1 ...
Страница 84: ...FOCKE MELER GLUING SOLUTIONS 9 4 SPARE PARTS LIST B PLATEN ENSEMBLE 2 3 4 5 7 8 6 1 ...
Страница 86: ...FOCKE MELER GLUING SOLUTIONS 9 6 SPARE PARTS LIST C SIMPLE MANIFOLD ENSEMBLE 7 5 13 14 9 10 11 12 3 4 2 1 6 8 ...
Страница 88: ...FOCKE MELER GLUING SOLUTIONS 9 8 SPARE PARTS LIST C DOUBLE MANIFOLD ENSEMBLE 4 12 2 3 6 5 8 7 9 10 11 1 ...
Страница 98: ...FOCKE MELER GLUING SOLUTIONS 9 18 SPARE PARTS LIST This page is intentionally left blank ...