
INSTALLATION
3-9
MA-5066-ENG
PS200 DRUM MELTER MANUAL
contact
NO
contact
NO
4. Reconnect the card connector.
5. Make sure that the cable is well connected and that its path through
the electrical cabinet presents no risks of snagging, being cut or any
other accidental deterioration.
Output inhibitor
1. If this is the only signal being connected, use a seven-wire cable no
smaller than 0.22 mm
2
.
2. Open the door to the electrical cabinet as far as possible. Thread the
power cord (Ø4-8 mm) through the electrical wall bushing Pg16 and
fasten it to the inside anchor, making sure that the cord reaches the
power card connector at the position where it will be installed.
3. Remove the connector from the card and connect the two cable wires
to their corresponding connector terminals:
1
voltage output
2
input for inhibitor output 1
3
input for inhibitor output 2
4
input for inhibitor output 3
5
input for inhibitor output 4
6
input for inhibitor output 5
7
input for inhibitor output 6
8
without connection.
4. Reconnect the card connector.
5. Make sure that the cable is well connected and that its path through
the electrical cabinet presents no risks of snagging, being cut or any
other accidental deterioration.
It is possible to select the channels that you want to control from the outside
using the small switches located above the connecter. Switches 1 through 6
control each of the channels, so that the switch in the ‘ON’ position means
heating from the equipment, without any external control.
When the switch is in the ‘OFF’ position, the corresponding channel does not
heat unless activated from the outside, through a non-voltage contact between
pin 1 (the common pin) and the pin that corresponds to the channel.
1 2 3 4 5 6 7 8
1
2
Содержание PS200
Страница 1: ...MA 5066 ENG 250220 GLUING SOLUTIONS ADHESIVE MELTER PS200 DRUM UNLOADER INSTRUCTIONS MANUAL ...
Страница 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 34: ...FOCKE MELER GLUING SOLUTIONS S A 3 12 INSTALLATION This page is intentionally left blank ...
Страница 68: ...FOCKE MELER GLUING SOLUTIONS S A 4 34 MELTER OPERATION ...
Страница 75: ...ELECTRICAL DRAWINGS 7 1 MA 5066 ENG PS200 DRUM MELTER MANUAL 7 ELECTRICAL DRAWINGS ...
Страница 76: ...FOCKE MELER GLUING SOLUTIONS S A 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 78: ...FOCKE MELER GLUING SOLUTIONS S A 8 2 PNEUMATIC DIAGRAMS 1 2 3 4 5 6 9 8 7 11 12 10 13 14 ...
Страница 80: ...FOCKE MELER GLUING SOLUTIONS S A 8 4 PNEUMATIC DIAGRAMS This page is intentionally left blank ...
Страница 82: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST A STRUCTURE 7 5 4 6 2 3 9 8 1 ...
Страница 84: ...FOCKE MELER GLUING SOLUTIONS 9 4 SPARE PARTS LIST B PLATEN ENSEMBLE 2 3 4 5 7 8 6 1 ...
Страница 86: ...FOCKE MELER GLUING SOLUTIONS 9 6 SPARE PARTS LIST C SIMPLE MANIFOLD ENSEMBLE 7 5 13 14 9 10 11 12 3 4 2 1 6 8 ...
Страница 88: ...FOCKE MELER GLUING SOLUTIONS 9 8 SPARE PARTS LIST C DOUBLE MANIFOLD ENSEMBLE 4 12 2 3 6 5 8 7 9 10 11 1 ...
Страница 98: ...FOCKE MELER GLUING SOLUTIONS 9 18 SPARE PARTS LIST This page is intentionally left blank ...