4-5
MA-5066-ENG
PS200 DRUM MELTER MANUAL
MELTER OPERATION
Display and adjustment of the working speed
The pump rotation speed (in revolutions per minute) is shown on the
display for each pump control card on the equipment. These revolutions
may be adjusted by using the up/down arrow keys (pumping speed, internal
reference), through a voltage signal from the main machine or by modifying
the full scale (pumping speed, external reference). The pump rotation speed
must be adjusted to the requirements of the application.
Warning
: Although rotation speeds can be selected between 0 and 100 rpm
it is not advisable to operate at speeds of less than 10 rpm (the flow may
become inconstant depending on the motor load) or greater than 80 rpm
(pump operating at maximum revolutions).
Note:
for further information on adjusting working speeds, see the section
‘Modes of operation’.
Temperature adjustment
The melters leave the factory with the following set point temperature values:
• 160 °C (320 °F) for the melting platen and distributor.
• 150ºC for the hoses and 160ºC for the applicators.
• °C displayed.
Code
Source
Actions
Heating
Pump
Main machine signal
Err 0
platen broken sensor
only platen off
off
off
Err 1
hose1 broken sensor
only hose1 off
off
off
Err 2
applicator1 broken sensor
only applicator1 off
off
off
Err 3
hose2 broken sensor
only hose2 off
off
off
Err 4
applicator2 broken sensor
only applicator2 off
off
off
Err 5
hose3 broken sensor
only hose3 off
off
off
Err 6
applicator3 broken sensor
only applicator3 off
off
off
Err 7
hose4 broken sensor
only hose4 off
off
off
Err 8
applicator4 broken sensor
only applicator4 off
off
off
Err 13
pump manifold broken sensor
only pump manifold off
off
off
Err 100
platen overheating
all components off
off
off
Err 101
hose1 overheating
all components off
off
off
Err 102
applicator1 overheating
all components off
off
off
Err 103
hose2 overheating
all components off
off
off
Err 104
applicator2 overheating
all components off
off
off
Err 105
hose3 overheating
all components off
off
off
Err 106
applicator3 overheating
all components off
off
off
Err 107
hose4 overheating
all components off
off
off
Err 108
applicator4 overheating
all components off
off
off
Err 113
pump manifold overheating
all components off
off
off
Содержание PS200
Страница 1: ...MA 5066 ENG 250220 GLUING SOLUTIONS ADHESIVE MELTER PS200 DRUM UNLOADER INSTRUCTIONS MANUAL ...
Страница 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 34: ...FOCKE MELER GLUING SOLUTIONS S A 3 12 INSTALLATION This page is intentionally left blank ...
Страница 68: ...FOCKE MELER GLUING SOLUTIONS S A 4 34 MELTER OPERATION ...
Страница 75: ...ELECTRICAL DRAWINGS 7 1 MA 5066 ENG PS200 DRUM MELTER MANUAL 7 ELECTRICAL DRAWINGS ...
Страница 76: ...FOCKE MELER GLUING SOLUTIONS S A 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 78: ...FOCKE MELER GLUING SOLUTIONS S A 8 2 PNEUMATIC DIAGRAMS 1 2 3 4 5 6 9 8 7 11 12 10 13 14 ...
Страница 80: ...FOCKE MELER GLUING SOLUTIONS S A 8 4 PNEUMATIC DIAGRAMS This page is intentionally left blank ...
Страница 82: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST A STRUCTURE 7 5 4 6 2 3 9 8 1 ...
Страница 84: ...FOCKE MELER GLUING SOLUTIONS 9 4 SPARE PARTS LIST B PLATEN ENSEMBLE 2 3 4 5 7 8 6 1 ...
Страница 86: ...FOCKE MELER GLUING SOLUTIONS 9 6 SPARE PARTS LIST C SIMPLE MANIFOLD ENSEMBLE 7 5 13 14 9 10 11 12 3 4 2 1 6 8 ...
Страница 88: ...FOCKE MELER GLUING SOLUTIONS 9 8 SPARE PARTS LIST C DOUBLE MANIFOLD ENSEMBLE 4 12 2 3 6 5 8 7 9 10 11 1 ...
Страница 98: ...FOCKE MELER GLUING SOLUTIONS 9 18 SPARE PARTS LIST This page is intentionally left blank ...