run the tool without parameters, a short usage screen is shown, explaining all
parameters it may understand. See appendix for a printout of this usage screen.
User defined Alarm scripts
You can define your own alarm script for every event by using the “Edit user
defined notification script”. This script will be called automatically if one of the
selected events occurs. This user alarm script will be stored on the Flash-Disk at
“/mnt/flash/user_defined_notification”. This script will be called with index and the
alarm message as text. The index value of the test message is 0.
NTP Client Monitoring
You can monitor a group of NTP clients and supervise the time offset, the NTP
stratum value and if the client is reachable or not. With the button „edit client list“
you can edit the list of clients to monitor. You can add the TCP/IP address or the
hostname of the client:
You can monitor the current states of the configured clients:
72