Menu: Network Services
The possible network protocols and access methods can be configured. After
pressing the OK button you can enable/disable SSH, TELNET, SNMP, FTP, IPV6,
HTTP, HTTPS and NETBIOS by using the UP/DOWN Keys and navigate through
the list with the LEFT/RIGHT keys. After you saved your settings with the “OK”
button, all these subsystems are stopped and eventually restarted (only if they are
enabled, of course).
Menu: System
In this submenu system specific parameters can be changed.
With
Time Zone
the time zone displayed on the front panel display can be
configured (see below).
With
Restart NTP
you can stop the currently running NTP daemon and restart it
afterwards.
The command
Reboot System
reboots the Linux operating system
– the build-in reference clock will not be restarted.
When
Factory Reset
is called, all system parameters will be reset to initial values.
However the parameters of each network interface do not change
Menu: Time Zone
The time zone of the time that is shown on the front panel display can be set up
here. The internal time zone of the timeserver and the time of NTP will always be
UTC. These parameters will not affect the serial output lines and the timecode (IRIG)
outputs. These parameters have to be configured in another menu
(Reference Time->Setup Outputs)
59
Global Cfg.
Interfaces
->Services <-
> SSH:x< IPv6:x
TELN:x HTTP:x
SNMP: NETB:
FTP: HTTPS:x
Ref. Time
Time Service
Network
->System <-
> Time Zone <
Restart NTP
Reboot System
Factory Reset
Содержание M900
Страница 1: ...Technical Information Operating Instructions M900 GPS PZF Redundant SHS ...
Страница 21: ...Assembly with CN UB E 21 ...
Страница 48: ...48 ...
Страница 64: ...Configuration Ethernet 64 ...
Страница 69: ...Configuration Notification 69 ...
Страница 74: ...Configuration Security 74 ...
Страница 87: ...Configuration Local 87 ...
Страница 95: ...Configuration Statistics 95 ...
Страница 144: ...IRIG Standard Format 144 ...
Страница 145: ...AFNOR Standard Format 145 ...