Programmable pulse (Option)
At the male connector type VG64 there are optionally three programmable TTL
outputs (Prog Pulse 1-3), which are arbitrarily programmable.
SETUP POUT X
This menu is used for configuration of the pulse outputs. There are three pulse outputs
available (POUT 1-3).
Progr: Puls
Out 1:TIMER
Out 2:CYCLIC
Out 3:PASSIV
With the arrow key right or OK Button the parameters of each programmable pulse
output can be set:
Progr. Pulses
->Output 1 <-
Output 2
Output 3
Each programmable pulse output has its own Mode to be set. With the arrow keys
up and down the mode can be selected:
->POUT1:PASSIV<-
POUT1:TIMER
POUT1:SINGLE
POUT1:CYCLIC
POUT1:PPS
POUT1:PPM
POUT1:PPH
Mode
This field selects the mode of operation of an output. Possible modes are PASSIV,
TIMER, SINGLE, CYCLIC, PPS, PPM and PPH.