Chapter 1 - Installation
LED Indicators
16
Mediatrix 1204
LED Patterns
Table 10
describes the different states a Mediatrix unit can have and their associated LED patterns.
Table 10:
States and LED Patterns
State
Description
LEDs Pattern
Ready
In Use
LAN
Power
Booting
Follows a hardware start or a reset.
See
“Booting LED Pattern Description”
Normal
Mode
“Normal” state of the unit where calls can be
initiated. Each LED has a separate behaviour.
See
AdminMode Calls are not permitted and maintenance actions
can be performed.
See
Recovery
Mode
The IP addresses for local host, image server,
syslog server, etc., are temporarily set to known
values. Calls are not allowed.
Blink
1 Hz
75%
Off
Misc.
a
Blink
1 Hz
75%
Reset
Pending
Triggered when the
Default Settings
switch is
pressed and held for at least 2 seconds.
Off
Off
Off
Blink
1 Hz
50%
Reboot
Pending
Triggered when the
Default Settings
switch is
pressed in either the
ResetPending
or
RecoveryMode Pending
states. The unit prepares
for a physical shutdown and restart.
Off
Off
Off
Off
Recovery
Mode
Pending
Triggered when the
Default Settings
switch is held
at start-time or for at least 7 seconds.
Blink
1 Hz
50%
Blink
1 Hz
50%
Blink
1 Hz
50%
Blink
1 Hz
50%
Default
Settings
Pending
Triggered when the
Default Settings
switch is not
released while in
RecoveryModePending
state.
At run time, if the
Default Settings
switch is
released within 5 seconds, the unit applies default
settings, otherwise the action is cancelled and the
unit goes back to the Operation Modes state or it
resets.
At start time, the unit stays in this state until the
Default Settings
switch is released. The unit then
applies the default settings and restarts.
On
On
On
On
Image
DownloadIn
Progress
A software image is downloaded into the unit and
written to persistent storage.
LEDs are blinking at 1 Hz 75%,
one at a
time
, from left to right.
Image
Download
Error
Triggered after a failure of an image download
operation. After 4 seconds, the unit restarts.
Blink
2 Hz
50%
Blink
2 Hz
50%
Blink
2 Hz
50%
Blink
2 Hz
50%
InitFailed
Triggered when bad initialization parameters are
detected and the unit cannot start correctly.
Note
: If the network configuration is dynamic, the
unit stays in the
Booting
state and continues to
query the DHCP until it receives valid values. If
the configuration is static, the LED pattern
indicates that the unit must be reset to default
settings or put into recovery mode for
maintenance and correction of network values.
Off
Off
Blink
4 Hz
50%
Off
Содержание Mediatrix 1204
Страница 6: ...Mediatrix Telecom a Division of Media5 Corporation Reference Manual...
Страница 26: ...Preface About this Manual End User Technical Support xxvi Mediatrix 1204...
Страница 27: ...Installation and Web Page Configuration...
Страница 28: ...Page Left Intentionally Blank...
Страница 50: ...Chapter 1 Installation Verifying the Installation 24 Mediatrix 1204...
Страница 98: ...Chapter 4 Web Interface SIP Parameters SIP Authentication 72 Mediatrix 1204...
Страница 127: ...SNMP Configuration...
Страница 128: ...Page Left Intentionally Blank...
Страница 162: ...Chapter 8 IP Address and Network Configuration Ethernet Connection Speed 136 Mediatrix 1204...
Страница 170: ...Chapter 9 SIP Servers Presence Compositor Server 144 Mediatrix 1204...
Страница 174: ...Chapter 10 DNS SRV Configuration DNS SRV Oriented Settings 148 Mediatrix 1204...
Страница 196: ...Chapter 12 Configuration File Download Configuration File Example 170 Mediatrix 1204...
Страница 220: ...Chapter 14 Gateway Configuration Detecting a Far End Disconnect 194 Mediatrix 1204...
Страница 240: ...Chapter 16 Voice Transmissions User Gain 214 Mediatrix 1204...
Страница 288: ...Chapter 23 Telephony Attributes Delayed Hot Line 262 Mediatrix 1204...
Страница 294: ...Chapter 25 Quality of Service QoS VLAN 268 Mediatrix 1204...
Страница 298: ...Chapter 26 Syslog Daemon Syslog Daemon Configuration 272 Mediatrix 1204...
Страница 302: ...Chapter 27 Statistics RTP Statistics 276 Mediatrix 1204...
Страница 319: ...Appendices...
Страница 320: ...Page Left Intentionally Blank...
Страница 332: ...Appendix B Standard Hardware Information Warranty 306 Mediatrix 1204...
Страница 336: ...Appendix C Cabling Considerations RJ 11 Telephone Cable 310 Mediatrix 1204...
Страница 372: ...Appendix E Glossary Wide Area Network WAN 346 Mediatrix 1204...
Страница 390: ...Index W 364 Mediatrix 1204...