September 2020
Electrocution Hazard
ELECTROCUTION HAZARD! THIS MACHINE IS NOT INSULATED!
DEATH OR SERIOUS INJURY will result from contact with or inadequate
clearance from any electrically charged conductor�����
You must maintain a CLEARANCE OF AT LEAST 10 FEET (3�����05 m)
between any part of the machine, or its load, and any electrical line or
apparatus carrying over 300 Volts up to 50,000 Volts����� One foot (30�����5 cm)
additional clearance is required for every additional 30,000 Volts�����
Observe Minimum Safe Approach Distance�����
Art_4193
Art_3467
This machine
is not
electrically insulated and
will not
provide protection from
contact with or proximity to electrical current.
Maintain safe distances from electrical power lines and apparatus in
accordance with applicable government regulations and the following chart:
Mnmum Save Approach Dstance Chart
Voltage
Minimum Safe Approach Distance
Phase to Phase
Feet
Meters
0 to 300 Volts
Avoid Contact
Over 300V to 50kv
10
3.1
Over 50KV to 200KV
15
4.6
Over 200KV to 350KV
20
6.1
Over 350KV to 500KV
25
7.6
Over 500KV to 750KV
35
10.7
Over 750KV to 1,000KV
45
13.7
Allow for platform movement, electrical line sway or sag and beware of strong
or gusty winds.
Keep away from the machine if it contacts energized power lines. Personnel
on the ground or in the platform must not touch or operate the machine until
energized power lines are shut off.
Do not use the machine as a ground for welding.
Electrocution Hazard
Secton 4 - Hazards