Page 29
Ttan Boom
TM
60-S - Operator’s Manual
September 2020
Secton 7 - Operatng Instructons & Functon Tests
Pressing the Emergency Stop Switch will stop deployment.
ART_3354
Chassis Level Switch
Use this control to manually change the level of the chassis. This function is
cut out when the boom is elevated.
Note:
This function is performed automatically when deploying the stabilizers.
Test Operation
Press and hold the Function Enable button.
Push the switch left or right. The chassis of the machine will move in the direction the switch is
pushed.
Boom Functions Control Lever
This control lever controls the Boom Extend/Retract and the Boom Lift/Lower functions. The control
lever is fully proportional for both functions.
These functions may be enabled by pressing the button on top of the control lever.
When the stabilizers are not deployed, boom extension is limited to approximately 14.25 feet (4.3
m). Deploying the stabilizers allows the machine to reach full extension and elevation.
ART_3370
Test Operation
To test the Boom Extend/Retract function; Extension cutout function:
With the stabilizers retracted, press and hold the Function Enable
button.
Push and hold the joystick to the right until the boom stops
extending. The boom should extend approximately 14.25 feet (4.3
m), then stop.
Push and hold the joystick to the left to retract the boom
completely.
Deploy the stabilizers.
Push and hold the joystick to the right until the boom reaches full
extension.
Push and hold the joystick to the left to retract the boom.
•
•
•
•
•
•
To test the Boom Lift/Lower function:
Press and hold the Function Enable button.
Pull the joystick back to lift the boom. Lift the boom completely.
Push the joystick forward to lower the boom. Lower the boom to its stowed position.
•
•
•
•
•
•