Page 45
Ttan Boom
TM
60-S - Operator’s Manual
September 2020
Secton 9 - Mantenance
Lubrication
Operator may perform routine maintenance only. Lubrication listed as Scheduled Maintenance must
be performed by a qualified service technician.
ART_4209
LEVEL
Add Oil Here
Beneath
Module Cover
Hydraulic Fluid
Sight Gauge
Fill to Here
3
1
2
Controls Module
Diesel Fuel
Sight Gauges
No�����
Item
Specification
Frequency
1
Hubs
SAE 90 Multipurpose Hypoid Gear Oil
API Service Classification GL5
Scheduled Maintenance
Check every three months or 150 hours,
whichever occurs first
Change yearly or every 600 hours,
whichever occurs first
2
Hydraulic
Reservoir
Fluid Type
Mobile 424
Mobile DTE13M
Mobile DTE11M
Temperature Range
> 30° F (0° C)
0° F (-18° C) ~ 30° F (0° C)
< 0° F (-18° C)
Routine Maintenance
Check level daily
Scheduled Maintenance
Change yearly or every 600 hours,
whichever occurs first
Do not substitute other fluids as pump
damage may result�����
Fill to the middle of the sight gauge with platform
in the stowed position and stabilizers retracted.
3
Hydraulic
Filter
Filter Element
(located inside Hydraulic Reservoir)
Scheduled Maintenance
Normal Conditions
Change every six months or 300 hours,
whichever occurs first
Severe Conditions--very dusty,
exceptionally hot or exceptionally cold
conditions
Change every three months or 150 hours,
whichever occurs first