Page 32
Ttan Boom
TM
60-S - Operator’s Manual
September 2020
Secton 7 - Operatng Instructons & Functon Tests
Emergency Lowering System
If the control system fails while the platform is elevated, use the
emergency lowering procedure to safely lower the platform�����
Do not climb down the boom assembly or exit the platform�����
ART_5657
Base Controls
Platform Controls
Emergency
Lowering Switch
Emergency
Lowering Switch
Emergency
Lowering Switch
The Emergency Lowering System is used to lower the platform in case of power failure. To lower the
platform, activate the Emergency Power Switch to run the Emergency Down auxiliary hydraulic pump.
This function uses battery power from the auxiliary battery to lower the platform.
Push and hold the Auxiliary Power switch, then use the Boom Extend/Retract function to retract
the boom.
Continue to hold the Auxiliary Power switch, then use the Boom Lift/Lower function to lower the
boom.
Note:
The Emergency Lowering System is disabled when the engine is running.
Note:
The Emergency Power switch serves as an enable switch. It is not necessary to use the
primary function enable switch.
•
•