![Mec Titan Boom 60-S Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/mec/titan-boom-60-s/titan-boom-60-s_operators-manual_1758607034.webp)
Page 30
Ttan Boom
TM
60-S - Operator’s Manual
September 2020
Secton 7 - Operatng Instructons & Functon Tests
ART_3364
Platform Level Switch
The Platform Level switch manually adjusts the angle of the platform support
beam.
Test Operation
The Platform Level function is controlled automatically as the boom is raised and lowered.
To manually level the platform:
Press and hold the Function Enable button.
Push the Platform Level switch up or down to adjust the position of the platform.
Platform Level power is disabled upon exceeding 5° out of level. Power is allowed only to the
direction that returns the platform toward level.
Platform Functions Control Lever
The Platform Functions control lever controls the Platform Slide Forward/Reverse and Platform
Rotate functions. The control lever is fully proportional for both functions.
These functions may be enabled by pressing the button on top of the control lever.
ART_3365
Test Operation
To test the Platform Slide Forward/Reverse function:
Press and hold the Function Enable button.
Push the control lever up to slide the platform forward.
Push the control lever down to slide the platform rearward.
To test the Platform Rotate function:
Press and hold the Function Enable button.
Push the control lever left to turn the platform counterclockwise.
Push the control lever right to turn the platform clockwise.
•
•
•
•
•
•
Note:
The Platform Rotate function will stop when the platform reaches its center position. To
continue to rotate the platform, return the joystick to the neutral position, then push the joystick
to rotate the platform in the desired direction.
•
•
•