POWER DOOR LOCK SYSTEM
DOOR LOCK TIMER UNIT INSPECTION
1. Remove the lower panel.
2. Measure the voltage at the door lock tim er unit term inals as indicated below.
3. Disconnect the door lock tim er unit connector before inspecting for continuity at term inals K, L, M, and N.
• If not as specified, inspect the parts listed under “Action.”
• If the parts and w iring harnesses are okay but the system still does not w ork properly, replace the door
lock tim er unit.
Terminal voltage list (Reference)
O
M
K
I
G
E
C
A
p
N
L
J
H
F
D
B
HARNESS SID E CO NN ECTO R
(VIEW FROM HARNESS SIDE)
Terminal
Signal
Connected to
Test condition
Voltage (V)/
Continuity
Action
A
Power supply
DOOR LOCK
30 A fuse
Under any condition
B +
• Inspect DOOR LOCK 30 A
fuse
■ Inspect related harness
B
Double lock
output (with
double locking
system)
• Door lock
actuator
• Liftgate lock
actuator
Door lock actuator is
double locked
0—>B + —>0
• Inspect door lock actuator
• Inspect liftgate lock actuator
• Inspect related harness
Other
0
C
Unlock output
• Door lock
actuator
• Liftgate lock
actuator
Door lock actuator is
unlocked
0->B + ->0
• Inspect door lock actuator
• Inspect liftgate lock actuator
• Inspect related harness
Other
0
D
Lock output
• Door lock
actuator
• Liftgate lock
actuator
Door lock actuator is
locked
0—>B + —»0
• Inspect door lock actuator
• Inspect liftgate lock actuator
• Inspect related harness
Other
0
E
-
-
-
-
-
F
Lock/Unlock
input
• Door key
cylinder
switch
• Keyless unit
Key cylinder had been
locked
*2.5
5
• Inspect key cylinder switch
• Inspect related harness
Key cylinder had been
unlocked
0
Key cylinder at neutral
position
*5
B+
Transmitter lock button
is pressed
*5—>2.5—>5
B
h
—>5—>B+
• Inspect keyless unit
• Inspect transmitter
• Inspect related harness
Transmitter unlock
button is pressed
*5—>0-»5
B+—>0—>B+
G
-
-
-
-
-
H
Security light
output (with
double locking
system)
Instrument
cluster
Double locking system
operated
1.4
• Inspect instrument cluster
• Inspect related harness
Other
B +
I
IG1 (with
double locking
system)
METER 7.5 A
fuse
Ignition switch at ON
position
B +
• Inspect METER 7.5 A fuse
• Inspect ignition switch
• Inspect related harness
Ignition switch at
LOCK or ACC position
0
J
Key reminder
switch (with
double locking
system)
Key reminder
switch
Key reminder switch at
on
B +
• Inspect key reminder switch
• Inspect related harness
Other
0
: With double locking system or theft-deterrent system
S -17
Содержание 626 Station Wagon
Страница 25: ...CONTROL SYSTEM WIRING DIAGRAM With Immobilizer System OUTLINE F1 4 ...
Страница 179: ...OUTLINE SYSTEM WIRING DIAGRAM S m ç g fT I C g 3 3 21 A m Hi p È a t ï S 3 M h d 0H ÜB 1 Hl J e F2 3 ...
Страница 183: ...CONTROL SYSTEM COMPONENT LOCATION F2 7 ...
Страница 204: ...MANUAL TRANSAXLE FEATURES OUTLINE J 2 OUTLINE OF CONSTRUCTION J 2 SPECIFICATIONS J 2 D J 1 ...
Страница 206: ...AUTOMATIC TRANSAXLE GF4A EL FEATURES OUTLINE K1 2 OUTLINE OF CONSTRUCTION K 1 2 SPECIFICATION K1 2 K1 1 ...
Страница 266: ...SHIFT MECHANISM 6 Apply grease to the cam as shown K2 59 ...
Страница 418: ...TROUBLESHOOTING KEYLESS ENTRY SYSTEM ON BOARD DIAGNOSTIC FUNCTION S 37 ...
Страница 454: ...WARNING AND INDICATOR SYSTEM O p e ra tin g O rd e r T 32 ...