35
–
Displaying the Multi-Zone detector's status reports at the Remote Control
RM-1
There are two ways to access the detector's status report
(the option
Reports
)
:
a. Through the main screen (option No.5), where you will be able to review only the
detector's status reports stored in the Remote Control memory.
b. Through the general programming list (option No. 22), where you will be able to read
(draw) the detector's status report to the Remote Control and even to save it there.
Here is the route to that programming list:
Detectors
Multi-Zone
Exist Device
Enter Device Code
…
Program Detector
Reports
(Option No. 22).
Reading (drawing) the detector's status report to the Remote Control
1. Make sure the detector's case is totally closed.
2. Press in the Remote Control:
Detectors
Multi-Zone
Exist Device
Enter Device Code
Program Detector
Reports
Read Report
(option No. 22).
3. Now you will be requested to enter the Date & Time, and to confirm by pressing
ENTER
.
4. The Remote Control will display the information it reads from the detector. It will look
like this:
- You can move in the report lines by using the arrow keys
↑ ↓
- If you press
ENTER
on a selected text, the text will be enlarged for your convenience.
Vin=08.0V
Temp.= 31
0
C
Vin connect.-15/08/11 14:56
LOW Vin EVENTS - 001
Vin connection counter-004
15/08/11 14:57
00/00/00 00:00
00/00/00 00:00
00/00/00 00:00
MASK ALARM EVENTS-001
15/08/11 14:57
00/00/00 00:00
00/00/00 00:00
00/00/00 00:00
16/05/12
16:45
MAXIMUM
Security (1984) Ltd.
Report Time
Report Date
Temperature
Inside detector
Date & Time of
last Vin
connection
Vin connection
Counter
Low Vin Counter
Date & Time of
the four last Vin
Events
Date & Time of
the four last
Anti-masking
Alarm Events
Anti-masking
Alarm Counter
Report Time
Input Voltage