Specifications
Power Supply
12V DC
Current drain
Standby 45 mA, Maximum 130 mA
Alarm relay contacts withstand (RELAY1,
RELAY2)
15V, 30 mA
Resistance of anti-masking relay contacts
(MASK)
15V, 30 mA
Resistance of tamper switch contacts
15V, 30 mA
Warm-up time
1 minute
Alarm relay activation time
2 seconds by default (programmable
between 1 second to 99 minutes. See
pages 16 paragraph 21).
Anti-masking relay (MASK) activation time
2 seconds at least and for as long as the
masking exists.
Anti-masking response time
About 1 minute (Programmable from 1 to
99 cycles. Each cycle takes 3 seconds.
See pages 16 paragraph 20).
Detection range
Horizontal angle
– up to 180
0
.
Distance of up to 12 meters (See page 5-
9).
Operating temperature
-37 to + 70
0
C