26
–
Programming (assigning) a code to the detector
1 .Connect the power supply to the detector and wait 60 seconds for the detector to warm
up.
During that time, a 60 second countdown begins in the detector's built-in display. When
the countdown ends, 3 short tones will be heard to indicate that the detector is now
ready for work.
During the countdown, red, green and yellow LED indicators will blink one after another
on the top of the detector.
2. Verify detector case is opened.
3. Switch ON the Remote Control and select:
DETECTORS
Multi-Zone
NEW DEVICE
4. ENTER CODE [ - - - - ] (Enter a 4 digit code you assign to the detector).
5
.
Aim the Remote Control towards the detector, then press
SEND
(the power key).
6. Once the code from the Remote Control is received by the Detector, the Remote
Control screen will display
OK
.
Entering programming and programming execution
Remarks
1. All the features that can be set/ programmed in the Multi-Zone detector by means of
the
RM-1
Remote Control are described in details on pages 28-34.
2. Once you program (change) any feature value, in most cases, you need to enter
SAVE to validate the change you did.
3. In order to program the detector, its case must be closed.
1. Make sure the detector
’s case is closed and the anti-masking study procedure is
completed.
2. Switch ON the Remote Control and select:
DETECTORS
Multi-Zone
Exist Device
3. ENTER CODE [
- - - -
] (Enter the 4 digit detector code you wish to handle).
4. Press
ENTER
5
.
Press READ DETECTOR if you want to extract the detector
’s parameter list to the
Remote Control.
Then, you will have 3 options:
a. Save, under any name, the parameters in the Remote Control memory.
b. Modify the parameters in the Remote Control and
SEND
them back to the detector