22
–
The detector full functionality test
The test should be performed when detector case is closed and LED indicators are
enabled (See page 15 paragraph 11).
The test procedure for human movement detection (Alarm):
o
Walk in the protected area.
o
Compulsory reaction of the detector:
Upon each detection event, the alarm RELAY1 will be operated for 2 seconds (default
time).
The following LED indicators will blink simultaneously during those 2 seconds: Red +
Green + Yellow.
In case the buzzer is enabled, a tone will be heard during this time.
Test procedure for masking detection (Anti-masking):
o
Place a white piece of paper at a distance of about 10 cm from the front of the
detector.
o
Compulsory reaction of the detector:
The Green LED will instantly blink continuously as long as the masking object exists.
If the masking object exists for more than 90 seconds, the orange LED will glow
continuously,
and the "MASK” (Anti-masking) relay will be operated for at least 2
seconds and for as long as the masking exists.