31
–
No.
Feature
Display
Description
Common
characteristic
17
PIR movement
detection direction
Left
Middle
F4
In order to activate the
alarm RELAY1, there
should be a detection by
the Left PIR sensors pair
and then in the Middle
PIR sensors pair
Detection
direction
18
PIR movement
detection direction
Left
Middle
F5
In order to activate the
alarm RELAY1, there
should be a detection by
the Middle PIR sensors
pair and then in the Left
PIR sensors pair
19
PIR movement
detection direction
Middle
Right
F6
In order to activate the
alarm RELAY1, there
should be a detection by
the Middle PIR sensors
pair and then in the Right
PIR sensors pair
20
PIR movement
detection direction
Right
Middle
F7
In order to activate the
alarm RELAY1, there
should be a detection by
the Right PIR sensors
pair and then in the
Middle PIR sensors pair
21
PIR movement
detection direction
Left
Middle
Right
F8
In order to activate the
alarm RELAY1, there
should be a detection by
the Left PIR sensors pair,
then in the Middle PIR
sensors pair and then in
the Right PIR sensors
pair.
22
PIR movement
detection direction
Right
Middle
Left
F9
In order to activate the
alarm RELAY1, there
should be a detection by
the Right PIR sensors
pair, then in the Middle
PIR sensors pair and
then in the Left PIR
sensors pair.
23
Time limit between
Left PIR sensors pair
detection and Middle
PIR sensors pair
detection.
T1
Between one detection
event of PIR sensors pair
and the following one
there is a period of time.
Here you can program
Time limit
between two
PIR sensors
pair detection
events.