15
–
activated.
No.
Feature
Display
Description
Common
characteristic
11
LED indicators
WT
Enable/Disable LED
indicators
LED
indicators
12
Tone indication
BZ
Enable/Disable tone
indication upon each
detection event.
Tone
indication
13
Shock & Vibration
detection sensitivity
VB
Programming the Shock
& Vibration detection
sensitivity from 00 to 99
(00 = Disabled).
Shock &
Vibration
detection
sensitivity
14
Left PIR sensors pair
sensitivity and pulse
count
P1
Programming the left PIR
sensors pair sensitivity
(00 to 63). If the display
shows "- -" it means that
the upper PIR sensor
was programmed with
different value than lower
PIR sensor (see
paragraphs 37, 38 of this
table).
If you press
OK
once
again, you can program
now the pulse count (01 -
11).
PIR sensors
pair sensitivity
and pulse
count
15
Middle PIR sensors
pair sensitivity and
pulse count
P2
Programming the Middle
PIR sensors pair
sensitivity (00 to 63). If
the display shows "- -" it
means that the upper PIR
sensor was programmed
with different value than
lower PIR sensor (see
paragraphs 39, 40 of this
table).
If you press
OK
once
again, you can program
now the pulse count (01 -
11).
16
Right PIR sensors
pair sensitivity and
pulse count
P3
Programming the Middle
PIR sensors pair
sensitivity (00 to 63). If
the display shows "- -" it
means that the upper PIR
sensor was programmed
with different value than