![MAXIMUM Security Multi Zone Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/maximum-security/multi-zone/multi-zone_manual_1744855028.webp)
-
28
–
Programming the detector by the Remote Control
No.
Feature
Display
Description
Common
characteristic
1
LED indicators
WT
Enable/disable LED
indicators
LED indicators
2
Tone indication
BZ
Enable/disable tone
indication upon each
detection event.
Tone indication
3
Shock & vibration
detection sensitivity
VB
Programming the shock
& vibration detection
sensitivity from 00 to 99
(00 = disabled).
Shock &
vibration
detection
sensitivity
4
Left PIR sensors pair
sensitivity and pulse
count
P1
Programming the Left
PIR sensors pair
sensitivity (00 to 63). If
the display shows "- -" it
means that the upper PIR
sensor was programmed
with different value than
lower PIR sensor (see
paragraphs 37 and 38 of
this table).
You can program the
pulse count as well (01 -
11).
PIR sensors
pair sensitivity
and pulse
count
5
Middle PIR sensors
pair sensitivity and
pulse count
P2
Programming the Middle
PIR sensors pair
sensitivity (00 to 63). If
the display shows "- -" it
means that the upper PIR
sensor was programmed
with different value than
lower PIR sensor (see
paragraphs 39 and 40 of
this table).
You can program the
pulse count as well (01 -
11).
6
Right PIR sensors
pair sensitivity and
pulse count
P3
Programming the Middle
PIR sensors pair
sensitivity (00 to 63). If
the display shows "- -" it
means that the upper PIR
sensor was programmed
with different value than
lower PIR sensor (see