Programming Table
No.
Feature
Display
Description
Common
characteristic
1
Highest detection
sensitivity
M0
The detector is equipped
with 8 preset detection
programs for your choice,
from the highest
detection sensitivity (M0)
to the lowest detection
sensitivity (M7).
8 preset
detection
programs for
your choice
2
Very High detection
sensitivity
M1
3
High detection
sensitivity
M2
4
Medium-plus
detection sensitivity
M3
5
Medium detection
sensitivity
M4
6
Low detection
sensitivity
M5
7
Very Low detection
sensitivity
M6
8
Lowest detection
sensitivity
M7
9
Assigning relay to
each pair of PIR
sensors.
Configuration No. 1
M8
RELAY1 will be activated
upon detection in the
right pair of PIR sensors
or upon anti-masking
detection.
RELAY
2 will be
activated upon detection
in the middle pair of PIR
sensors or upon anti-
masking detection.
MASK relay will be
activated upon detection
in the left pair of PIR
sensors or upon Anti-
masking detection.
Assigning
relay to each
pair of PIR
sensors.
For test
purposes.
10
Assigning relay to
each pair of PIR
sensors.
Configuration No. 2
M9
RELAY1 will be activated
upon detection in the
right pair of PIR.
RELAY
2 will be
activated upon detection
in the middle pair of PIR.
MASK relay will be
activated upon detection
in the left pair of PIR.
Upon anti-masking
detection in any PIR pair,
MASK relay will be