16
–
lower PIR sensor (see
paragraphs 41, 42 of this
table).
If you press
OK
once
again, you can program
now the pulse count (01 -
11).
No.
Feature
Display
Description
Common
characteristic
17
Left Microwave
sensor detection
sensitivity and Pulse
Count
M
.
W
Programming the Left
Microwave sensor
detection sensitivity (00
to 63).
If you press
OK
once
again, you can program
now the pulse count (01 -
50).
Microwave
sensor
detection
sensitivity and
Pulse Count
18
Middle Microwave
sensor detection
sensitivity and Pulse
Count
MW
.
Programming the Middle
Microwave sensor
detection sensitivity (00
to 63).
If you press
OK
once
again, you can program
now the pulse count (01 -
50).
19
Right Microwave
sensor detection
sensitivity and Pulse
Count
M
.
W
.
Programming the Right
Microwave sensor
detection sensitivity (00
to 63).
If you press
OK
once
again, you can program
now the pulse count (01 -
50).
20
Anti-masking
detection sensitivity
and response time.
AM
Anti-masking detection
sensitivity (00-10).
If you press
OK
once
again, you can program
now the anti-masking
response time (01 -99
test cycles, duration of
each cycle is about 3
seconds).
Anti-masking
detection
sensitivity and
response
time.
21
RELAY1 activation
time and logics (N.C.
/ N.O.)
R1
RELAY1 activation time
(1-99 Seconds or
Minutes).
When the two decimal
points appear, the given
RELAY
activation time
and logics
(N.C. / N.O.)