25
–
INTRODUCTION
RM-1
is a remote control device that works with the Multi-Zone detector and other
products of MAXIMUM Security (1984) Ltd.
RM-1
is an optional product and complementary accessory for Multi-Zone. It can be
purchased separately.
This guide refers to the operation of RM-1 with the Multi-Zone detector only.
Below is a partial list (*) of features you can set/ program in the Multi-Zone detector by
means of the
RM-1:
1. PIR sensitivity and pulse count for each of six PIR sensors.
2. Microwave sensitivity and pulse count for each of the three Microwave sensors.
3. Movement direction to be detected by the detector.
4. Anti-masking sensitivity.
5. Activation time and the logics (N.C. / N.O.) of each of the three relays.
6. Time limit between two PIR sensors pair detection events.
7. LED indicators enabling/ disabling.
8. Enabling/ disabling of a tone heard upon each detection event.
9. Sensitivity of shock & vibration sensor.
10.
RM-1
Remote Control can display the detectors' technical status report and a report
of detection history of each detector.
(*) All features that can be set/ programmed in the Multi-Zone detector by means of the
RM-1
Remote Control are described in details on pages 27-33.
Power ON/ OFF
The power button is located in the top right corner of the keyboard.
A short press will switch ON the Remote Control.
To switch OFF the Remote Control, press and hold the power button until it switches OFF
(press for about 2 seconds).
Switching OFF would be possible only after you exit the menu to an upper level.
In order to extend the battery life, the Remote Control power will go OFF automatically if
its keyboard is not in use for more than 3 minutes.
Navigation
There are 2 ways to enter any feature menu:
1. Use the arrows to select the required feature, then press ENTER.
2. Directly enter the number alongside the required feature.
Do the same to set the value/ parameter once you are inside the feature menu.