4 Advanced Operation
4-6
4-5-3 Setting the Current Program with External Voltage
0 to Rating Current is controllable with external voltage, 0 to 10V. (4 at SW1 to be ON)
4-5-4 Setting the Current Program with External Resistance
0 to Rating Current is controllable with external resistor, 0 to 10kΩ. (2 at SW1 to be ON)
4-6 Monitor/Status Output
4-6-1 Monitor Output
0 to Rating Voltage/Current are able to be monitored with 0 to 10V.
(5 and 6 at SW1 to be OFF)
TB1
0-10VDC
+
5
2
-S
(Common)
User connection
Power supply unit
Internal circuit
ON
SW1
1
8
TB1
0-10kΩ
5
2
-S
(Common)
+
0-1mA
-
Power supply unit
Internal circuit
User connection
ON
SW1
1
8
5
1
Output current monitor
0-10VDC
-
15
3
0-10VDC
1kΩ
14
18
0-10VDC
1kΩ
-
+
-S
(Common)
Power supply unit
Internal circuit
User connection
-
+
+
V
Output voltage monitor
0-10VDC
V
-
+
TB1
ON
SW1
1
8