2 Installation and Operation
2-5
2-4 Overview of Panels
2-4-1 Front Panel(750W to 1.2kW Type)
2-4-2 Rear Panel(750W to 1.2kW Type)
Input voltage:AC115V/AC230V
100V/200V for L(200V)
110V/220V for L(220V)
120V/240V for L(240V)
Input phase:1φ
Input frequency:50/60Hz
FLT
LD
EXT
CV
CC
REN
① ② ③
④
⑤⑥
⑦
⑧
⑨⑩
⑪
⑫ ⑬
⑭
⑮
⑯
Matsusada
SET
OVP
OUTPUT
POWER
REGULATED DC POWER SUPPLY
VOLTAGE
CURRENT
V
A
⑩
Voltage mode indicator
⑪
Current mode indicator
⑫
Output voltage/output current preset switch
⑬
OVP setting switch
⑭
OVP setting volume
⑮
Output voltage setting volume(dial for Potentiometer at LLp option.)
⑯
Output current setting volume(dial for Potentiometer at LLp option)
①
POWER ON/OFF switch
②
OUTPUT ON/OFF switch
③
OUTPUT-ON indicator LED
④
Fault indicator
⑤
External switch OFF indicator
⑥
Remote programming indicator
⑦
Volt meter
⑧
Current meter
⑨
Remote enable indicator for GP-IB
①
Connector for remote control(D-sub 25-pin)
②
Function setting switch
③
Connector terminals for options
④
-Sens connector
⑤
+Sens connector
⑥
-Output bus bar
⑦
+Output bus bar
⑧
-Output terminal(M5)
⑨
+Output terminal(M5)
⑩
Exhaust
⑪
AC input terminal board
③
⑥
⑦
⑫
①
②
④
⑤
⑩
⑪
⑧ ⑨
TB1
SW1
Terminals are used for output when
output current is 60A or lower.
AC115V
INPUT
SHORT
AC
115V/230V 1φ
AC230V
50V60Hz
OPEN
N L