2 Installation and Operation
2-15
2-6-2 Case of Connecting Load Accompanied by Excessive Ripple Current
・
The life of this product is much influenced by load (ON/OFF or short circuited load) which is
fraught with excessive ripple current such as plasma discharge. Take action such as inserting a
low-pass filter between this product and load when you use such a load continuously
generating ripples. If it is the case of repetitive period less than 1 second of short-circuit or
bubble without countermeasure,
there might be the possibility of causing damage of the product due to electrolytic liquid
leakage, etc, so quit the usage and contact our sales agent.
・
There might be the case where the life of this product is much influenced by excessive ripple
current for loads such as inverter load or ECU. If you use a load in which excessive ripple
current flows, you should take action inserting a capacitor between the product and the load at
position close to the load side.
If you use the product without countermeasure, there might be the possibility of causing
damage of the product due to smoke generation, electrolytic liquid leakage, etc, so quit the
usage and contact our sales agent.
* Consult our sales agent for tolerance value on current ripple, etc.
Low-pass
Filter
Load
Output -
PS
Output +
Output
-
Load
C