34
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
LED control
panel lights
do not light
up.
1. No power supply.
2. Damaged wiring or loose
connection.
3. Wiring not attached to control
panel switch.
4. Defective switch.
5. Defective LEDs.
box.
2. Check all wiring connections between
the battery box and the LED. Also
check the connections between the
LEDs on the control panel.
3. Check the connection between the
LED and the LED switch.
4. Replace the switch.
5. Replace the LED.
Cooking light
will not turn
on.
1. No power supply.
2. Defective Halogen bulb.
3. Internal wiring issue.
1. Check power supply and make sure it
is properly plugged in.
2. Replace the bulb.
3. Check the wiring connections under
the fire box. All wire connections must
be tight. If any wires are damaged
they should be replaced.
1. Install 9V batteries in the LED battery
Содержание 0098162