Option “2” in SNMP menu is for configuring each parameter. After pressing option “2”, user will be
prompted for command value of each parameter shown in above figure. The command number of each
parameter are mentioned in left most column of parameters list. User can do configuration of multiple
values at a time by entering the command value of required parameter. User will remain in the
configuration menu till user enters “0” in command prompt. User can use “H” for displaying list of all
parameters in middle of configuration stage.
Once all required parameters are configured, operator can save the set parameters using “0” command
and then press “y” or “Y” (yes) when prompted for saving. Whenever user is in middle of configuration
mode option and want to check the command options of other parameters of same mode, user can press
“H” for help.
Below table provide each parameter description for SNMP parameters.
Command For
SNMP
Version
Parameter
Applicable
Value
Description
1
v1
&
v2c
Manager 1 IP address
Valid IPv4/IPv6
address
SNMP Manager1 v4/v6 IP
address
Default: 0.0.0.0
2
v1
&
v2c
Manager 1 Version
0 / 1 / 2 /3
This should be set according
to SNMP Version of Manager
1.