Model: MTS200 (1U)
Doc. Ref. no. : m08/om/201
Issue no. : 03
User’s Manual
Page 56 of 195
Page 56 of 195
Configuration of Eth0 (EthX) Parameters
1. Bonding
Here, user can configure bonding if MTS200 is with two Ethernet ports. In case of bonding "ENABLE",
only configurations of Ethernet port 0 will be applicable to bonding.
To configure bonding of Ethernet port 0 and 1, user have to select "ENABLE" for BONDING and press
OK key to save changes as shown in figure.
In case of bonding both Ethernet port will be using common IP address and other network setting for IPv4
as well as IPv6. MAC address of interface will be same as particular Ethernet port's MAC address which
one is active.
Note:
To configure bond, user need to configure Ethernet 0's configuration parameters.
User can view active Ethernet port for bonding on display in RUNMODE.
Bonding is preferred when user want both Ethernet port to be worked in same network.
2. ETH v4 ADDRESS
Her, user can configure IPv4 address for specific port as shown in figure. If DHCP is "ENABLE" for
respective port, this configurations will not affect IPv4 address.
*
: Cursor will start blinking once user enters this mode by pressing “OK” key, user can see blinking
cursor on 1
st
position of 2
nd
line. To change specific digit, use “UP” / “DOWN” arrow keys and to change
th
e position of blinking cursor use “LEFT” / ”RIGHT” arrow keys. UP/DOWN arrow keys will update the
digit on which cursor is blinking.
After value is edited, press “OK” again to save the parameter or "ESC" to restore parameter value. After
user presses “OK” key, user can view changed IPv4 address.
3. ETH v4 SUBNETMASK