2. NTP Sync Loss [OID:- .1.3.6.1.4.1.38306.7.1.3.0]
Message: “ NTP Sync.” or “NTP Not Sync.”
Description: Whenever ntpd daemon in device loses sync with internal gps receiver,
mas
TER
T-
Sync
will generate this alarm on every change of state. This may happen at every power up of
device or ntp service restart of stop/start or internal accuracy loss or manual change of internal
system clock.
3. NTP service restart/start/stop trap [OID:- .
.1.3.6.1.4.1.38306.7.1.4.0]
Message: “NTP Srvs. Stop” or “NTP Srvs. Start” or “NTP Srvs. Restart”
Description: Whenever the ntp service is restarted or stopped or started manually through front
panel keypad or SSH/Telnet application program or SNMP application or at power-up when
device comes in LOCK from unlock condition, this trap is generated.
4. Unit configuration change alarm [OID:- .1.3.6.1.4.1.38306.7.1.5.0]
Message: “Config. Changed”
Description: This alarm is generated whenever there is any change in configuration of device
done through front panel keypad or SSH/Telnet application program or SNMP application.
SNMP traps can be received through running snmptrapd utiltity in unix/linux based systems or configuring
SNMP MIB Browser software on windows based systems.
13.4 Webserver
User/Operator need to carefully read and apply applicable notes before using MTS200 webserver
.
Note:
1. MTS200 configuration through webserver should be accessed through a single computer at a
time to avoid any configuration conflict through multiple computer systems.
2. It is recommended to use IE 9.0+, Mozilla Firefox 46+ web-browser software for MTS200
webserver.
Use shortcut “Ctrl + F5” instead of F5 key to refresh the webpage.
3. If user is using
“Google Chrome” or any other web-browser software, it is recommended to clear
cache and cookies before starting MTS200 webserver.
4. It is recommended to clear cookies and cache files from web browser after power on of MTS200
unit. This will avoid any user conflict with old caches files of MTS200 device in web-browser with
current MTS200 data.
5. As, MTS200 uses cookies for some of its webserver page features, user should not block the
cookies settings for MTS200 webserver pages.
6.
If user is using IE (Internet Explorer) for webserver, user need to do following changes in IE
settings. Go to
Internet Options
->
Browsing history
->
Settings
->
select option “Every
Time I Visit the Webpage”
->
OK
. This option will make web browser to load latest webpage
from MTS200 webserver. Refer below two images for detail.