DSM570
User’s Manual
Page 68
Revision 1.8.3
•
Disable
– the channel is disabled and transmits no data over the NMEA 2000 network
6.5.3.3 Instance
From here the instance number used in the message send for this channel may be set.
6.5.3.4 Source
This parameter is present only when the channel has been configured for the function of
Temperature, Pressure, Humidity, or Flow Rate. This parameter selects the type of temperature,
pressure, humidity, or flow rate measurement being performed so that displays can more easily select
the data from the network.
6.5.3.5 Value at 4mA
Program this parameter to match the reading of the current loop transducer when it is sourcing a
current of 4mA. You can determine this value by examining the specification of the transducer being
used.
6.5.3.6 Value at 20mA
Program this parameter to match the reading of the current loop transducer when it is sourcing a
current of 20mA. You can determine this value by examining the specification of the transducer being
used.
6.5.3.7 Data Damping Period
You can configure a damping parameter to smooth the parametric readings or make them more
responsive. The data damping is configurable between 0.1-25.0 seconds. The default data damping
period is 3.0 seconds.
\\richpc\maretron\Projects\DCM\DCM100\Manual\Configuring DCM100 with DSMxxx.docx
Содержание DSM570
Страница 98: ...DSM570 User s Manual Page 82 Revision 1 8 3 Figure 70 DSM150 DSM250 DSM410 DSM570 Remote Device Selection...
Страница 166: ...DSM570 User s Manual Page 150 Revision 1 8 3 Figure 154 RAA100 Setting the to Sender Gauge Resistance...
Страница 223: ...Revision 1 8 3 Page 207 Figure 239 Compass Rose North Up Display...
Страница 243: ...Revision 1 8 3 Page 227 Figure 269 Favorite Screen Showing Highlighted Switch Breaker...