6.3.1.2 Current Transformer B
The ACM100 with firmware revision 1.0.7 or newer supports two different types of current sensors:
the 100A current sensor included with the unit and an optional 400A current sensor. This menu entry
allows you to indicate which type of current sensor you have installed for phase B.
6.3.1.3 Current Transformer C
The ACM100 with firmware revision 1.0.7 or newer supports two different types of current sensors:
the 100A current sensor included with the unit and an optional 400A current sensor. This menu entry
allows you to indicate which type of current sensor you have installed for phase C.
6.3.1.4 Current Transformer A
If you notice that the power measurements of phase A are negative when they should be positive, or
vice-versa, then the current transformer has been installed backwards. If this happens, then instead
of reconnecting the current transformer, you may change the value of this parameter from the default
value
of “Normal Install” to “Inverse Install” to correct for this.
Valid options are:
•
Inverse Install
•
Normal Install
Use the
Scroll Up
and
Scroll Down
buttons to select the correct option, and then press
Enter
to
save the value.
6.3.1.5 Current Transformer B
If you notice that the power measurements of phase B are negative when they should be positive, or
vice-versa, then the current transformer has been installed backwards. If this happens, then instead
of reconnecting the current transformer, you may change the value of this parameter from the default
value of
“Normal Install” to “Inverse Install” to correct for this.
Valid options are:
•
Inverse Install
•
Normal Install
Use the
Scroll Up
and
Scroll Down
buttons to select the correct option, and then press
Enter
to
save the value.
6.3.1.6 Current Transformer C
If you notice that the power measurements of phase C are negative when they should be positive, or
vice-versa, then the current transformer has been installed backwards. If this happens, then instead
of reconnecting the current transformer, you may change the value of this parameter from the default
value of “Normal Install” to “Inverse Install” to correct for this.
Valid options are:
•
Inverse Install
•
Normal Install
Содержание DSM570
Страница 98: ...DSM570 User s Manual Page 82 Revision 1 8 3 Figure 70 DSM150 DSM250 DSM410 DSM570 Remote Device Selection...
Страница 166: ...DSM570 User s Manual Page 150 Revision 1 8 3 Figure 154 RAA100 Setting the to Sender Gauge Resistance...
Страница 223: ...Revision 1 8 3 Page 207 Figure 239 Compass Rose North Up Display...
Страница 243: ...Revision 1 8 3 Page 227 Figure 269 Favorite Screen Showing Highlighted Switch Breaker...