Revision 1.8.3
Page 85
be altered. The speed calibration process provides a method for the actual STW reading produced by
the DST100 to be adjusted within the DSM570 (i.e., calibration data is not stored within the DST100).
WARNING: Unlike resetting the trip log and setting the depth offset, which actually programs
the DST100 so that all displays receive the same information, speed calibration must be
performed at individual displays in order to show calibrated speed through water.
6.9.4 Transducer Depth Offset
The DSM570 can set the transducer depth offset parameter in a DST100 depth/speed/temperature
transducer. If you are interested in the actual water depth (as opposed to the depth beneath the keel),
then you should program a positive value equal to the distance from the waterline to the depth of the
DST100. The DSM570 will then add the measured depth of the water (as seen by the DST100) to the
programmed offset value to produce the total water depth. If you are interested in the depth of water
beneath the keel, then you should program a negative value equal to the distance between the
DST100 and the bottom of the keel. The display will then subtract the programmed offset from the
measured depth of the water (as seen by the DST100) showing you the depth of water beneath the
keel.
You program the transducer depth offset by pressing the
Enter
key (
) with the “Transducer Depth
Offset:” menu item selected which results in the screen shown in Figure 74.
Figure 74
– Setting the Transducer Depth Offset in a DST100
With the offset value highlighted, you can change the offset by using the
Increase
and
Decrease
keys
(
or
)
. Once you have selected the desired offset, push the
Enter
key (
) to complete
the transducer depth offset calibration. This procedure actually programs the offset value into the
DST100 such that all displays subsequently receive the offset information. This means you don’t have
to program multiple displays each with the corresponding offset information as the information is
stored at a single place (at the source).
6.9.5 Trip Log
The DSM570 is capable of clearing the trip log counter within a DST100 depth/speed/temperature
transducer. You zero the trip log by pressing the Enter key (
) with th
e “Trip Log:” menu item
selected which results in the screen shown in Figure 75. Pressing the
Accept
(
) key while the
Содержание DSM570
Страница 98: ...DSM570 User s Manual Page 82 Revision 1 8 3 Figure 70 DSM150 DSM250 DSM410 DSM570 Remote Device Selection...
Страница 166: ...DSM570 User s Manual Page 150 Revision 1 8 3 Figure 154 RAA100 Setting the to Sender Gauge Resistance...
Страница 223: ...Revision 1 8 3 Page 207 Figure 239 Compass Rose North Up Display...
Страница 243: ...Revision 1 8 3 Page 227 Figure 269 Favorite Screen Showing Highlighted Switch Breaker...