Revision 1.8.3
Page 189
Figure 214
– Rectangular Tank Calibration
Enter the distance from the face of the TLM100 sensor to the bottom of the tank for the
Empty Tank
Depth
, and the distance from the face of the TLM100 sensor to the top of the liquid when the tank is
full for the
Full Tank Depth
.
After entering the values, use the
Back
button to return the parent menu.
6.25.5
Tank Number
The Tank Number is the Data Instance used in the data message. This can be set from #0 to #15.
6.25.6
Tank Type
This is set to the type of fluid in the tank. Values are:
•
Fuel
•
Fresh Water
•
Waste Water
•
Live Well
•
Oil
•
Black Water
•
Reserved-1
..
Reserved-7
– These values may be used when the contents of the tank does not
fit into one of the categories above.
6.26 Maretron TLM150 Configuration
The TLM150 is the gasoline version of the TLM100. The configuration of the two devices is the same;
see Section 6.25 for details.
6.27 Maretron TLM200 Configuration
The TLM200 is the deep tank version of the TLM100. The configuration of the two devices is the
same; see Section 6.25 for details.