background image

 

DSM570 

User’s Manual  

 

 

Page 210 

 

 

Revision 1.8.3 

7.7 GPS Status Display 

The GPS Status display shows the following data about the selected GPS receiver: 
 

  GPS operating mode (2D, 3D, DGPS) 

  Satellite signal strength (up to 12 satellites) 

  Satellite azimuth and elevation (up to 12 satellites) 

  Position 

  HDOP 

  Time 

  Date 

  Accuracy of position 

 
An example of a full-screen GPS Status display can be seen below in Figure 244.  
 

 

Figure 244 

– GPS Status Display Example 

 

 

Содержание DSM570

Страница 1: ...3 Page i DSM570 NMEA 2000 Multi function Color Graphic Display User s Manual Revision 1 8 3 Copyright 2020 Carling Technologies Inc 60 Johnson Ave Plainville CT 06062 USA All Rights Reserved http www...

Страница 2: ...DSM570 User s Manual Page ii Revision 1 8 3 Revision History Revision Description 1 8 3 Original document...

Страница 3: ...3 3 2 Choosing a Value from a List 6 3 3 3 Entering a Numeric Value 6 3 3 4 Entering a Textual Value 6 3 4 Settings Lock Mode 8 4 Important Concepts 9 4 1 Favorite Screens 9 4 2 Categories and Data T...

Страница 4: ...2 6 Favorite Screens Setup Menu 36 5 2 7 Units Menu 41 5 3 Control Mode 45 6 Device Configuration 47 6 1 Airmar Depth Speed Temperature Transducers 50 6 1 1 Advanced Configuration 50 6 1 2 Device Ins...

Страница 5: ...ttings from local display 79 6 8 6 Copy DST100 calibrations from local display 80 6 8 7 Copy all settings from local display 80 6 8 8 Label 81 6 8 9 Remote Device Selection 81 6 9 Maretron DST100 Conf...

Страница 6: ...vice Label 123 6 14 5 SBAS WAAS Enable Disable 123 6 15 Maretron GPS200 Configuration 125 6 15 1 Advanced Configuration 125 6 15 2 Cold Start GPS 127 6 15 3 Device Label 127 6 15 4 SBAS WAAS EGNOS MSA...

Страница 7: ...3 1 Advanced Configuration 160 6 23 2 Installation Offset Calibration 163 6 23 3 Inverted Installation Entry 164 6 23 4 Label 165 6 23 5 Magnetic Deviation Calibration 165 6 23 6 Magnetic Deviation St...

Страница 8: ...97 6 31 1 Advanced Configuration 197 6 31 2 Device Label 199 6 31 3 Installation Offset Calibration 200 6 31 4 Wind Data Damping Period 202 6 31 5 Barometric Pressure 202 6 31 6 Outside Humidity 203 6...

Страница 9: ...6 Location 232 8 3 7 Trigger Configuration 232 8 3 8 Local Audible 246 8 3 9 Tone 247 8 3 10 Remote Annunciators 247 8 3 11 SMS Text Settings 248 8 3 12 Operating Mode Moored 249 8 3 13 Operating Mod...

Страница 10: ...een Format 38 Figure 25 Setting the Auto Change Interval 38 Figure 26 Selecting the Data Category 39 Figure 27 Selecting the Data to be displayed 39 Figure 28 DSM570 Units Menu 41 Figure 29 Device Con...

Страница 11: ...om local display 81 Figure 69 DSM150 DSM250 DSM410 DSM570 Label Configuration 81 Figure 70 DSM150 DSM250 DSM410 DSM570 Remote Device Selection 82 Figure 71 DST100 Configuration Screen 83 Figure 72 DST...

Страница 12: ...Cold Start of the GPS100 122 Figure 117 Configuring GPS Operating Mode on a GPS100 123 Figure 118 Configuring SBAS on a GPS100 124 Figure 119 GPS200 Configuration Screen 125 Figure 120 GPS200 Advance...

Страница 13: ...een 159 Figure 167 SSC200 SSC300 Configuration Screen 160 Figure 168 SSC200 SSC300 Advanced Configuration Screen 160 Figure 169 SSC200 SSC300 NMEA 0183 Settings Screen 161 Figure 170 SSC200 SSC300 NME...

Страница 14: ...libration Confirmation Screen 188 Figure 213 Rectangular Tank Selection 188 Figure 214 Rectangular Tank Calibration 189 Figure 215 TMP100 Configuration Screen 190 Figure 216 TMP100 Advanced Configurat...

Страница 15: ...Display 222 Figure 262 Trim Tab Display 222 Figure 263 Swing Meter Display 223 Figure 264 Tank Gauge Display 223 Figure 265 Watermaker Status Display 224 Figure 266 Configuration of Switch Breaker Di...

Страница 16: ...leting an Alert 250 Figure 295 Deleting Alert List 250 Figure 296 Deleting an Alert Confirmation 251 Figure 297 Editing an Alert 251 Figure 298 Editing an Alert Alert List 252 Figure 299 Setting the V...

Страница 17: ...ctions for installation configuration and usage of the Maretron DSM570 in order to ensure optimal performance 1 2 Firmware Revision This manual corresponds to DSM570 firmware revision 1 7 2 1 3 DSM570...

Страница 18: ...easy access to the rear side of the mounting surface The steps for this type of mounting are as follows 1 Attach the Mounting Template see Section 13 to the surface where the DSM570 is to be located...

Страница 19: ...ecurely and that the collar on the cable connector is tightened firmly Connect the other end of the cable male to the NMEA 2000 network in the same manner The DSM570 is designed such that you can plug...

Страница 20: ...elow Figure 2 DSM570 Power Up Screen Alternatively you may power down the DSM570 by pressing and holding the power key see Section 3 2 below for details 3 2 Turning the DSM570 Off To turn the DSM570 o...

Страница 21: ...ht brightness between three programmed brightness levels see Section 5 2 4 3 on page 32 for details while a long press cycles the DSM250 through 8 programmable color palettes see Section 5 2 4 4 on Pa...

Страница 22: ...Choosing a Value from a List When editing a value chosen from a list the keys on the DSM570 keypad have the following functions Power Key turns the DSM570 off see Section 3 1 on page 4 for details Bac...

Страница 23: ...ton top return to the choices on the left To append a numeral use the Scroll Up and Scroll Down buttons to select Numeric and then press Enter to go across to the numbers Now use the Scroll Up and Scr...

Страница 24: ...The DSM570 has a settings lock mode in which the settings of the DSM570 cannot be changed To enter the lock mode do the following steps 1 Begin with the DSM570 powered off 2 Press and hold the Up and...

Страница 25: ...settings data to display and formats in which to display the data The DSM570 supports up to 16 different favorite screens 4 2 Categories and Data Types The DSM570 is capable of displaying many types...

Страница 26: ...f the AC power on the generator Average L N Voltage displays average line to neutral RMS voltage of the AC power on the generator Average L L Voltage displays average line to line RMS voltage of the A...

Страница 27: ...utility Total Reactive Power displays reactive power output by the utility Total Apparent Power displays apparent power output by the utility Total Power Factor displays power factor of the utility T...

Страница 28: ...chor Drop position See Section 7 1 for details 4 2 5 DC The DSM570 supports the display of information for up to 64 DC sources including alternators batteries solar cells wind generators etc with spec...

Страница 29: ...at accumulates the elapsed time that the indicator has spent in the OFF state This timer may be reset with the control mode of the display see Section 5 2 7 14 for details Hardware ON Timer displays t...

Страница 30: ...urrent day and position Sunset displays the local time of sunset for the current day and position Dew Point displays the current dew point based on air temperature and humidity Temp Engine Room displa...

Страница 31: ...displays total fuel remaining in all fuel tanks specified within the favorite screen setup see Section 5 2 6 4 2 In order for the DSM570 to properly calculate total fuel remaining tank monitors connec...

Страница 32: ...to true or magnetic north depending on the unit setting of the heading parameter see Section 5 2 7 1 Rate of Turn displays the angular rate of rotation of the vessel about the vertical axis Variation...

Страница 33: ...otational Rate displays rotational rate e g shaft speed Velocity displays linear velocity 4 2 19 Navigation The DSM570 is not a primary navigation device that is it does not provide means for entering...

Страница 34: ...of the vessel s rudder as indicated by the rudder sensor as well as the angle to which the rudder has been commanded by an autopilot or steering device 4 2 22 SMS Text Status Status displays the stat...

Страница 35: ...al time offset see Section 5 2 7 12 on page 43 for details on how to set the local time offset UTC Date displays the current date referenced to Universal Time Coordinated Moon Phase displays the phase...

Страница 36: ...he horizontal axis perpendicular to the ship s keel Roll displays the roll of the vessel rotation about the horizontal axis parallel to the ship s keel Trim Tabs displays the position of the vessel s...

Страница 37: ...speed of the wind as it would appear to an observer if the vessel was stopped in the water calculated using speed through water STW or speed over ground SOG depending on the unit setting of the Wind...

Страница 38: ...of alert announcing a condition requiring immediate attention or user intervention Alarms are shown in red when Active and always appear above the warnings on the Alert Status Screen Warning A warnin...

Страница 39: ...tive Alert An Inactive alert may be disabled which causes it to transition to the Disabled state New alerts are created in the Inactive State Active An Active alert is an alarm or warning where the co...

Страница 40: ...the Set Delay field Tripped Alert The alert will become active if the monitored circuit breaker becomes Tripped for longer than the time specified in the Set Delay field Course Alert The alert will be...

Страница 41: ...ay can show any displayable data in any display type supported by that data In favorite screens mode the DSM570 can operate in one of two ways Manual mode a particular favorite screen remains on the d...

Страница 42: ...lowing structure Alert Setup 5 2 1 Add New Alert 8 2 Delete Alert 8 4 Edit Alert 8 5 Operating Mode 8 6 SMS Text Phone Book 0 Advanced Configuration 8 8 Restore Factory Defaults 8 9 Alert Status 5 2 2...

Страница 43: ...be received The available options within the Configuration screen are shown in Figure 8 Figure 8 Configuration Screen 5 2 3 1 Device Configuration The ability to calibrate and configure other devices...

Страница 44: ...es Online or has been disconnected from the bus has lost power or for some other reason is not responding to queries Offline The Display column indicates whether data from that particular device is ac...

Страница 45: ...lly advanced configuration is only done at installation and should not need to be done while at sea Figure 11 DSM570 Advanced Configuration 5 2 4 1 1 Installation Description This entry allows you to...

Страница 46: ...re 12 DSM570 Primary Device Selection 5 2 4 1 3 Refresh Network Information The Device Configuration 5 2 3 1 and Device Selection 5 2 3 2 menus display a list of devices that have been detected on the...

Страница 47: ...nected network given in bits per second bps Voltage the network voltage as measured by the DSM570 in Volts Traffic the percent usage of the total available bandwidth measured by the DSM570 Receive Rat...

Страница 48: ...he Low Medium and High brightness levels The value that appears next to the appropriate setting is measured in percent of full brightness The Backlight menu can be seen in Figure 15 below Figure 15 Ba...

Страница 49: ...ghts key when the DSM570 is operating in favorite screens mode Change the Color Set back to On to enable this color palette Notice that Color Set 1 has a white background 100 Red 100 Green and 100 Blu...

Страница 50: ...enter the demo mode while programming this option for Off Normal Use Mode will cause the DSM570 to return to using data from the NMEA 2000 bus In order to be able to demonstrate all of the DSM570 s ca...

Страница 51: ...nguages is planned for future firmware releases To change the currently used language use the Scroll Up or Scroll Down keys to move the highlight to the Language menu item and then press the Enter key...

Страница 52: ...s in which the DSM570 will display the next higher or lower numbered favorite screen respectively that is enabled for Manual mode Figure 21 Setting the Favorite Screens Mode 5 2 6 Favorite Screens Set...

Страница 53: ...will be displayed taking up the entire screen 2 3 Top 1 3 Bottom two parameters will be displayed the first occupying the top 2 3 of the screen and the second occupying the bottom 1 3 of the screen 1...

Страница 54: ...creen Four Quarters four parameters will be displayed the first occupying the upper left hand corner of the screen the second occupying the upper right hand corner of the screen the third occupying th...

Страница 55: ...pt this category at which time the highlight will move to the data type field where you can display the particular data type from the selected category to be displayed as shown in Figure 27 Figure 27...

Страница 56: ...on page 223 Watermaker Status see Section 7 25 on page 223 Switch Breaker Display see Section 7 25 on page 224 5 2 6 4 2 Instance Instance is used to specify which product on the network will be used...

Страница 57: ...SM570 Units Menu 5 2 7 1 Heading This menu item allows you to select whether heading course and bearing information is displayed in true or magnetic measurements True heading can only be displayed if...

Страница 58: ...d speed related information Units that may be selected are the following Knots Miles Hour Km Hour Beaufort Meters second 5 2 7 6 Wind True Vessel Ref This menu items allows you to select whether the t...

Страница 59: ...volume related information Units that may be selected are the following Liters Imperial Gallons UK Gallons Gallons US Gallons 5 2 7 11 Time Format This menu item allows you to select whether measureme...

Страница 60: ...rams Pounds 5 2 7 16 Resistance This menu item allows you to select the units to be used for the display of resistance Units that may be selected include the following Ohms Kilohms 5 2 7 17 Motion Dis...

Страница 61: ...e display of angular velocity Units that may be selected include the following Degrees Second Degrees Minute Radians Second Radians Minute RPM 5 2 7 22 Angular Acceleration This menu item allows you t...

Страница 62: ...value In normal operating mode use the Scroll Up and Scroll Down keys to change to the screen containing the display to be reset Once that screen is displayed follow these steps to reset the appropria...

Страница 63: ...log Maretron Depth Speed Temp Transducer DST110 reset trip log set depth offset speed calibration and temperature offset Maretron Engine Monitoring System EMS100 set the gauge types for boost pressure...

Страница 64: ...able disable individual NMEA 2000 PGN transmissions Maretron Tank Level Adapter TLA100 set tank type and tank number set operating mode set tank capacity and calibrate for irregular shaped tanks Maret...

Страница 65: ...ays the manufacturer of the device The Model column displays the model number of the device The SN column displays the serial number of the device so that any of two or more devices of the same manufa...

Страница 66: ...tion functions are supported not all functions apply to every model of transducer Reset trip log Set depth Offset Perform Speed Calibration Program Temperature Offset Figure 30 Airmar Depth Speed Temp...

Страница 67: ...isable menu item selected causes the DSM570 to display the NMEA2000 PGN Enable Disable screen You can enable or disable the transmission of these messages or set the frequency of transmission of the m...

Страница 68: ...a where you are sure there are no currents and calm winds Finally use the Increase and Decrease keys to adjust the display value until it matches the known speed of the boat Press the Accept key to ac...

Страница 69: ...epth beneath the keel then you should program a positive value equal to the distance from the waterline to the depth of the depth transducer The DSM570 will then add the measured depth of the water as...

Страница 70: ...formation This means you don t have to program multiple displays each with the corresponding offset information as the information is stored at a single place at the source 6 1 10 Trip Log The DSM570...

Страница 71: ...ngle entry Trim Tabs Calibration Figure 36 EP 30 Trim Tabs Configuration Screen 6 2 1 Trim Tabs Calibration The Bennett EP 30 NMEA1 trim tabs calibration opening screen is shown in Figure 37 below The...

Страница 72: ...ping in order for the calibration process to succeed Figure 38 EP 30 Intermediate Calibration Screen After you have lowered both trim tabs to their full down position and a few seconds have elapsed th...

Страница 73: ...be performed by an advanced user Typically advanced configuration is only done at installation and should not need to be done while at sea Figure 41 ACM100 Advanced Configuration Screen 6 3 1 1 Curren...

Страница 74: ...ormal Install to Inverse Install to correct for this Valid options are Inverse Install Normal Install Use the Scroll Up and Scroll Down buttons to select the correct option and then press Enter to sav...

Страница 75: ...it to a value in the range of 0 2 seconds to 10 seconds Use the Increase and Decrease buttons to select the correct option and then press Enter to save the value 6 3 1 9 Installation Description This...

Страница 76: ...two hot wires 180 out of phase with each other and single neutral wire from a single phase of a transformer a typical 220VAC connection in the US 3 Phase Y Phase A B C use this value when power is con...

Страница 77: ...on 3 3 4 for details on how to enter a textual value 6 3 6 Reset Total Energy Recorded The ACM100 will accumulate the total amount of energy produced by a Generator or a Utility Pressing the Enter key...

Страница 78: ...es some complex parameters within the device and should only be performed by an advanced user Typically advanced configuration is only done at installation and should not need to be done while at sea...

Страница 79: ...DSM570 to display the following screen Figure 46 Figure 46 ALM100 NMEA 2000 PGN Enable Disable Screen You can enable or disable the transmission of the Annunciator message or set the frequency of tran...

Страница 80: ...e device over the network Typically this label will describe the location of the ALM100 See section 3 3 4 for details on how to enter a textual value 6 4 4 Test Annunciator The Annunciator may be test...

Страница 81: ...is only done at installation and should not need to be done while at sea Figure 48 CLM100 Advanced Configuration Screen 6 5 1 1 Device Instance This entry allows you to program the NMEA 2000 device i...

Страница 82: ...MEA 2000 PGN Enable Disable Screen You can enable or disable the transmission of these messages or set the frequency of transmission of the message by pressing the Enter key on the message to be confi...

Страница 83: ...ly this label will describe the function or location of the sensor 6 5 3 2 Function The CLM100 can support 4 20mA current loop transducers of many different types This field allows you to select the t...

Страница 84: ...Value at 4mA Program this parameter to match the reading of the current loop transducer when it is sourcing a current of 4mA You can determine this value by examining the specification of the transduc...

Страница 85: ...n the device and should only be performed by an advanced user Typically advanced configuration is only done at installation and should not need to be done while at sea Figure 52 DCR100 Advanced Config...

Страница 86: ...layed Figure 54 DCR100 Current Sensor Zero Offset Calibration Completion Screen Press the Back button to return to the previous menu 6 6 1 2 Device Instance This entry allows you to program the NMEA 2...

Страница 87: ...Screen 6 6 1 5 Restore Factory Defaults This option restores all settings on the device to their factory default state 6 6 2 Device Label This entry allows you to assign a text label to the device Thi...

Страница 88: ...Switch Lock mode is Unlocked In the Unlocked mode the channel may be turned on and off from network display devices By setting the Switch Lock mode of the channel to Lock then channel will not change...

Страница 89: ...ng mode of each channel may be set to either DCR DC Relay in which case the state of the channel is controlled by Circuit Breaker Switch controls in N2KView or Switch Breaker favorite screens in the D...

Страница 90: ...Remote Device Selection A DSM570 unit can be used to configure a remote DSM200 to set which NMEA 2000 devices are selected for display on the remote DSM200 unit In this manner multiple devices of the...

Страница 91: ...he bus has lost power or for some other reason is not responding to queries Offline The Disp column indicates whether data from that particular device is accepted for display by the remote DSM200 On o...

Страница 92: ...ure 60 DSM150 DSM250 DSM410 DSM570 Remote Configuration Screen 6 8 1 Remote Device Selection A DSM570 unit can be used to configure a remote DSM150 DSM250 DSM410 DSM570 to set which NMEA 2000 devices...

Страница 93: ...by this device Off By scrolling to the device and pressing the Enter key you may then use the Scroll Up and Scroll Down keys to toggle the Display status for this particular device Once you are satis...

Страница 94: ...copy the device selection settings from a DSM570 unit to a remotely located DSM150 DSM250 DSM410 DSM570 In this way it is possible to make all device selection changes on a single DSM150 DSM250 DSM41...

Страница 95: ...item and pressing Enter all the favorite screen settings will be copied from the local DSM150 DSM250 DSM410 DSM570 to the selected remote DSM150 DSM250 DSM410 DSM570 unit After copying favorite screen...

Страница 96: ...SM250 DSM410 DSM570 Figure 67 DSM150 DSM250 DSM410 DSM570 Copy DST100 calibrations from local display 6 8 7 Copy all settings from local display This is the single operation that makes it easy to have...

Страница 97: ...vice Figure 68 DSM150 DSM250 DSM410 DSM570 Copy all settings from local display 6 8 8 Label The Label of the DSM150 DSM250 DSM410 DSM570 is used by the Alert System to identify the source of an alert...

Страница 98: ...DSM570 User s Manual Page 82 Revision 1 8 3 Figure 70 DSM150 DSM250 DSM410 DSM570 Remote Device Selection...

Страница 99: ...ration Screen 6 9 1 Advanced Configuration Advanced Configuration changes some complex parameters within the device and should only be performed by an advanced user Typically advanced configuration is...

Страница 100: ...speed through water STW initial accuracy is significantly affected by the location or placement of the DST100 within the hull The DSM570 can correct for these inaccuracies using the speed calibration...

Страница 101: ...e equal to the distance between the DST100 and the bottom of the keel The display will then subtract the programmed offset from the measured depth of the water as seen by the DST100 showing you the de...

Страница 102: ...is selected will complete the operation Resetting the trip log zeroes the DST100 s trip log such that all displays receive a zeroed value i e you don t have to perform the operation from other display...

Страница 103: ...d Configuration Advanced Configuration changes some complex parameters within the device and should only be performed by an advanced user Typically advanced configuration is only done at installation...

Страница 104: ...tem selected causes the DSM570 to display the following screen Figure 78 DST110 NMEA 2000 PGN Enable Disable Screen You can enable or disable the transmission of these messages or set the frequency of...

Страница 105: ...matches the known speed of the boat Press the Accept key to accept the value when you are satisfied If you do not wish to perform speed calibration at this time press the Abort key and the speed calib...

Страница 106: ...ne to the depth of the DST110 The DSM570 will then add the measured depth of the water as seen by the DST110 to the programmed offset value to produce the total water depth If you are interested in th...

Страница 107: ...nding offset information as the information is stored at a single place at the source 6 10 7 Trip Log The DSM570 is capable of clearing the trip log counter within a DST110 depth speed temperature tra...

Страница 108: ...Screen First Screen Figure 84 EMS100 Configuration Screen Second Screen 6 11 1 Engine Instance This entry allows you to program the NMEA 2000 device instance for the unit You usually will not need to...

Страница 109: ...y from their specified values This setting allows you to apply an offset to the resistance value of the boost pressure sender in order to allow you to bring the digital value reported by the EMS100 in...

Страница 110: ...elect this option if there is no oil pressure gauge present YANMAR YANMAR W THRESHOLD YANMAR VDO YANMAR VDO W THRESHOLD Select the required option using the Scroll Up and Scroll Down keys followed by...

Страница 111: ...abled select this option if there is no water temperature sender present YANMAR YANMAR VDO Select the required option using the Scroll Up and Scroll Down keys followed by the Enter key 6 11 13 Water T...

Страница 112: ...ernator pulses per revolution in order to correctly calculate engine RPM Use this setting to program the EMS100 with the number of flywheel teeth or alternator pulses per revolution for the engine to...

Страница 113: ...user Typically advanced configuration is only done at installation and should not need to be done while at sea Figure 86 FFM100 Advanced Configuration 6 12 1 1 Device Instance This entry allows you to...

Страница 114: ...the default value of Yes for the FFM100 to output negative fuel flow values if the direction of fuel flow for the Channel 0 sensor is opposite the direction of the arrow on the fuel flow sensor label...

Страница 115: ...6 12 2 Device Label A label may be assigned to the FFM100 as an aid to identifying the device over the network Typically this label will describe the location of the FFM100 6 12 3 Operating Mode The F...

Страница 116: ...enshots below Figure 88 FFM100 Channel 0 First Configuration Screen Differential Mode Figure 89 FFM100 Channel 0 Second Configuration Screen Differential Mode 6 12 4 1 1 Channel Supply Return You may...

Страница 117: ...ram this parameter to match the desired instance number of the temperature reading for this channel You can program this parameter to any value between 0 and 252 The default value for this parameter i...

Страница 118: ...this channel Maretron display products will display this label text when you are selecting data to display 6 12 4 2 Channel 0 Configuration Menu Two Independent Sensors Mode This section describes the...

Страница 119: ...ensor connected to this channel 6 12 4 2 5 Data Damping Period You can configure a damping parameter to smooth the flow rate readings or make them more responsive The data damping is configurable betw...

Страница 120: ...13 Volume Instance Program this parameter to match the desired instance number of the volume reading for this channel You can program this parameter to any value between 0 and 252 The default value f...

Страница 121: ...ue for this parameter is 0 033 C which corresponds to Diesel fuel This parameter is not available when the Operating Mode is set to Two Individual Flow Sensors 6 12 5 1 4 Temperature Instance Program...

Страница 122: ...FFM100 Channel 1 First Configuration Screen Two Independent Sensors Mode Figure 94 FFM100 Channel 1 Second Configuration Screen Two Independent Sensors Mode 6 12 5 2 1 Sensor You may select whether th...

Страница 123: ...the total volume recorded to zero 6 12 5 2 7 Temperature Instance Program this parameter to match the desired instance number of the temperature reading for this channel You can program this parameter...

Страница 124: ...5 2 14 Volume Label Program this parameter with a text string which identifies the particular volume parameter being monitored by this channel Maretron display products will display this label text wh...

Страница 125: ...t strings You can enter any information you like here such as the date the unit was installed or the location in which it was installed for later reference Tools such as Maretron N2KAnalyzer allow you...

Страница 126: ...owed by the Enter key 6 13 1 4 Restore Factory Defaults This option restores all settings on the device to their factory default state 6 13 2 Channel 0 5 This submenu contains configuration parameters...

Страница 127: ...the specification of the pressure transducer being used 6 13 2 1 4 Pressure at 20mA Program this parameter to match the pressure reading of the pressure transducer when it is sourcing a current of 20...

Страница 128: ...the resistance of the sender with the fluid levels Custom calibration is necessary for non rectangular tanks and for non standard values of resistances for tank level senders To perform custom calibra...

Страница 129: ...ibration step Enter the first calibration point with an empty tank 0 0 Gallons liters by pressing the Accept key The Current Point highlight will advance to the next point Figure 102 Empty Level Calib...

Страница 130: ...process and will also adjust the tank capacity to the currently indicated level Figure 104 below shows the calibration screen at the last point with the full tank level and thus the tank capacity set...

Страница 131: ...r the depth of the fluid when the tank is full this is the distance from the surface of the fluid to the bottom of the tank Fluid Density enter the density of the fluid whose depth is being measured T...

Страница 132: ...nu when the channel s Function has been set to Pressure Vacuum mode The Channel 0 5 Pressure Vacuum Mode menu is shown below Figure 107 FPM100 Channel Pressure Vacuum Mode Configuration 6 13 2 2 1 Fun...

Страница 133: ...ing period is 16 0 seconds If the channel s Function is set to Pressure Vacuum the default data damping period is 3 0 seconds 6 14Maretron GPS100 Configuration This describes the configuration of the...

Страница 134: ...below Figure 109 GPS100 Advanced Configuration Screen 6 14 1 1 Device Instance The Device Instance will be used to identify the GPS100 device on the network Unless there are multiple GPSs on the netwo...

Страница 135: ...which causes the screen shown in Figure 111 to be displayed Figure 111 Configuring Satellite Elevation Mask on a GPS100 The allowable values for Elevation Mask are between 90 and 90 This number repre...

Страница 136: ...fix is obtained Disabling the PDOP Mask by setting the value to will cause the GPS100 to report any position fixes obtained regardless of the accuracy of the fix 6 14 1 5 SNR Mask The DSM570 is capab...

Страница 137: ...splay Pressing the Enter key with NMEA2000 PGN Enable Disable menu item selected causes the DSM570 to display the screen shown in Figure 114 Figure 114 GPS100 NMEA 2000 PGN Enable Disable Screen You c...

Страница 138: ...enu item selected which causes the screen shown in Figure 116 to be displayed This will cause the GPS100 to discard all position and satellite data and compute a position fix Figure 116 Performing a C...

Страница 139: ...allows the GPS to report any available data regardless of the quality of the fix 6 14 4 Device Label A label may be assigned to the GPS100 as an aid to identifying the device over the network Typical...

Страница 140: ...3 Figure 118 Configuring SBAS on a GPS100 The allowable options for SBAS configuration are either Disable which causes the GPS100 not to use SBAS satellites or Enable which causes the GPS100 to use SB...

Страница 141: ...ry Defaults configuration which allows you to return the GPS200 to the factory settings Figure 119 GPS200 Configuration Screen 6 15 1 Advanced Configuration Advanced Configuration changes some complex...

Страница 142: ...nu item selected causes the DSM570 to display the screen shown in Figure 114 Figure 121 GPS200 NMEA 2000 PGN Enable Disable Screen You can enable or disable specific transmissions by scrolling or thro...

Страница 143: ...position fix Figure 123 Performing a Cold Start of the GPS200 6 15 3 Device Label A label may be assigned to the GPS200 as an aid to identifying the device over the network Typically this would descri...

Страница 144: ...3 Figure 124 Configuring SBAS on a GPS200 The allowable options for SBAS configuration are either Disable which causes the GPS200 not to use SBAS satellites or Enable which causes the GPS200 to use SB...

Страница 145: ...Configuration Screen 1 1 2 Advanced Configuration Advanced Configuration changes some complex parameters within the device and should only be performed by an advanced user Typically advanced configur...

Страница 146: ...bout the N2KServer running on the IPG100 The following sections describe the entries in this menu Figure 127 IPG100 N2KServer Information Screen 6 16 1 3 1 Client List For each N2KView client connecte...

Страница 147: ...entry shows the number of platinum licenses in use followed by a slash followed by the total number of platinum licenses 6 16 1 3 5 Basic Licenses This entry shows the number of basic licenses in use...

Страница 148: ...rom any N2KView client whether it is a Windows PC or an iOS or Android smartphone or tablet If you have an active Maretron Cloud Services account you must change this setting to Enable so that the IPG...

Страница 149: ...ubnet mask the values define the network and must be the same The most common value is 255 255 255 0 If the DHCP parameter is set to Yes you do not need to configure this parameter If the DHCP paramet...

Страница 150: ...Screen 6 17 1 1 Data Damping In order to smooth the results viewed on a display you may individually change the data damping period that the J2K100 uses when sending fuel rate and tachometer engine RP...

Страница 151: ...es use the Scroll Up or Scroll Down keys to move the highlighted cursor to the J1939 Diagnostic Messages menu item Then press the Enter key to move the highlight to the value field which displays eith...

Страница 152: ...d causes the DSM570 to display the following screen Figure 134 J2K100 NMEA 2000 PGN Enable Disable Screen You can enable or disable specific transmissions by scrolling or through the different transmi...

Страница 153: ...ee section 6 17 4 identifies the engine on the J1939 network the Engine Instance identifies the engine to the NMEA2000 network Figure 135 J2K100 Engine Instance Configuration Use the Scroll Up and Scr...

Страница 154: ...nique instance identifier to allow display devices to distinguish it from other air conditioners or icemakers on the network The AC Icemaker menu item allows you to configure the air conditioner or in...

Страница 155: ...1939 engine genset or a single transmission and the NMEA 2000 network This setting identifies the J1939 source address of the engine genset and a transmission for which the J2K100 will serve as a gate...

Страница 156: ...of the screen To update the list after adding a device highlight this entry and press the Enter button 6 18Maretron NBE100 Configuration The DSM570 is capable of configuring the Maretron NBE100 Networ...

Страница 157: ...s You can enter any information you like here such as the date the unit was installed or the location in which it was installed for later reference Tools such as Maretron N2KAnalyzer allow you to view...

Страница 158: ...Device Instance This entry allows you to program the NMEA 2000 device instance for the unit You usually will not need to modify the default value of 0 unless you have multiple units on the network 6...

Страница 159: ...the Rudder message by pressing the Enter key on the message to be configured Options are Disable The status message will not be transmitted Default The status message will be transmitted at its defaul...

Страница 160: ...gle Calibration Options There are three methods of calibrating the rudder angle sender 6 19 3 1 Custom Calibration The Custom Calibration setting will provide the most accurate rudder angle readings u...

Страница 161: ...er Calibration menu item highlighted Figure 146 RAA100 Custom Rudder Angle Calibration The first step in the custom rudder angle sender calibration process is to turn the wheel hard over to starboard...

Страница 162: ...to turn the wheel hard over to port and to measure the angle or the rudder angle from center with a protractor or other instrument Use the Increase and Decrease keys until the highlighted rudder angle...

Страница 163: ...r must be configured For a vessel with a single rudder the number should be set to 0 For a vessel with two rudders the port rudder should be set to 0 and the starboard rudder should be set to 1 Each r...

Страница 164: ...ting be performed correctly in order for the RAA100 to produce correct angle measurements A screenshot showing configuration of the operating mode appears in Figure 152 below To configure the operatin...

Страница 165: ...press the Enter key to confirm your selection and store the value within the RAA100 Figure 153 RAA100 Setting the to Sender Gauge Resistance 6 19 7 Gauge Resistance to Sender If the desired operating...

Страница 166: ...DSM570 User s Manual Page 150 Revision 1 8 3 Figure 154 RAA100 Setting the to Sender Gauge Resistance...

Страница 167: ...IM100 Configuration Screen 6 20 1 Advanced Configuration Advanced Configuration changes some complex parameters within the device and should only be performed by an advanced user Typically advanced co...

Страница 168: ...000 PGN Enable Disable Screen You can enable or disable the transmission of the Binary Switch Status message or set the frequency of transmission of the message by pressing the Enter key on the messag...

Страница 169: ...are Disable the channel is not being used Enable the channel is being used Select the required option using the Scroll Up and Scroll Down keys followed by the Enter key 6 20 4 2 Label A label may be...

Страница 170: ...Figure 159 SIM100 Configuration Screen 6 21 1 Advanced Configuration Advanced Configuration changes some complex parameters within the device and should only be performed by an advanced user Typically...

Страница 171: ...nable Disable Screen You can enable or disable the transmission of the Binary Switch Status message or set the frequency of transmission of the message by pressing the Enter key on the message to be c...

Страница 172: ...ted as a fault condition See the manual for details Valid Modes are Disable the channel is not being used End Of Line Resistor an open circuit is a fault condition No End Of Line Resistor an open circ...

Страница 173: ...Figure 163 SMS100 Configuration Screen 6 22 1 Advanced Configuration Advanced Configuration changes some complex parameters within the device and should only be performed by an advanced user Typicall...

Страница 174: ...ure 165 Figure 165 SMS100 NMEA 2000 PGN Enable Disable Screen You can enable or disable the transmission of the various messages or set the frequency of transmission of the messages by pressing the En...

Страница 175: ...own on a scale of one to five bars Bit Error Rate This entry shows the bit error rate of the cellular network connection This figure may be requested by Maretron technical support personnel The middle...

Страница 176: ...seen in Figure 167 below Figure 167 SSC200 SSC300 Configuration Screen 6 23 1 Advanced Configuration Advanced Configuration changes some complex parameters within the device and should only be perform...

Страница 177: ...s value may be changed by selecting the Baud Rate option in the menu and pressing Enter The use the Scroll Up and Scroll Down buttons to select the desired baud rate and press Enter to save the value...

Страница 178: ...r reading and variation The SSC200 SSC300 always has magnetic heading available when variation is not available timeout or invalid the variation field is set to N A The default value of 5 0 seconds sh...

Страница 179: ...using the Scroll Up or Scroll Down keys followed by the Enter key 6 23 1 5 Restore Factory Defaults This option restores all settings on the device to their factory default state 6 23 2 Installation...

Страница 180: ...ntry Normally the SSC200 SSC300 is mounted so that the label on the compass is facing up and the NMEA 2000 and NMEA 0183 connectors are facing towards the bow of the vessel A recent version of SSC200...

Страница 181: ...SSC300 Magnetic Deviation Calibration Start Screen Once you have begun the turn press Begin to start the calibration procedure If you do not wish to perform magnetic deviation calibration at this time...

Страница 182: ...sful a screen will appear indicating this and you should repeat the calibration procedure 6 23 6 Magnetic Deviation Status Pressing the Enter key with the Magnetic Variation Status menu item selected...

Страница 183: ...the Enter key with the Rate of Turn Zero Offset Calibration menu item selected which causes the DSM570 to display the screen shown in Figure 179 The Rate of Turn Offset Calibration should be done bef...

Страница 184: ...to NMEA 0183 or NMEA 2000 factory default You should need to alter this setting only if There are variation sources available on both the NMEA 2000 and NMEA 0183 interfaces or There is no magnetic va...

Страница 185: ...nu item selected This highlights the next field where you select Manual Entry by scrolling or through the options until you reach Manual Entry Pressing the Enter key with the Manual Entry menu item se...

Страница 186: ...be available only in magnetic heading format WARNING Magnetic variation changes as your location on the earth changes therefore magnetic variation should be adjusted with changes in position Neither t...

Страница 187: ...reen 6 24 1 Advanced Configuration Advanced Configuration changes some complex parameters within the device and should only be performed by an advanced user Typically advanced configuration is only do...

Страница 188: ...owing screen Figure 186 Figure 186 TLA100 NMEA 2000 PGN Enable Disable Screen You can enable or disable the transmission of the Fluid Level message or set the frequency of transmission of the message...

Страница 189: ...you have pressed the Enter key a confirmation screen will appear that warns you that the fluid remaining measurement will change as a result of this change Press the Accept key to accept the change an...

Страница 190: ...e of the sender with the fluid levels Figure 189 below shows a screenshot of the DSM570 with the Custom Calibration option highlighted Custom calibration is necessary for non rectangular tanks and for...

Страница 191: ...ibration step Enter the first calibration point with an empty tank 0 0 Gallons liters by pressing the Accept key The Current Point highlight will advance to the next point Figure 191 Empty Level Calib...

Страница 192: ...process and will also adjust the tank capacity to the currently indicated level Figure 193 below shows the calibration screen at the last point with the full tank level and thus the tank capacity set...

Страница 193: ...tem and then press the Enter key to write the calibration values within the TLA100 and complete the calibration process Figure 195 American Standard Sender Calibration 6 24 4 3 European Standard Sende...

Страница 194: ...to move the highlighted cursor to Tank Number then press the Enter key to move the cursor over to the tank number value Use the Scroll Up or Scroll Down keys to select the desired tank number Finally...

Страница 195: ...des depending on the installation NMEA 2000 the only thing that is connected to the resistive sender is the TLA100 NMEA 2000 Analog Gauge in addition to the TLA100 the resistive sender is also connect...

Страница 196: ...hlighted cursor over the Gauge Resistance to Sender menu item Then press the Enter key to move the highlight over the numerical resistance value Use the Increase and Decrease keys to change the value...

Страница 197: ...esistance to Sender menu item Then press the Enter key to move the highlight over the numerical resistance value Use the Increase and Decrease keys to change the value to the measured resistance value...

Страница 198: ...202 TLM100 Configuration Screen 6 25 1 Advanced Configuration Advanced Configuration changes some complex parameters within the device and should only be performed by an advanced user Typically advan...

Страница 199: ...or disable the transmission of the Binary Switch Status message by pressing the Enter key on the message to be configured Options are Off The fluid level message will not be transmitted On The fluid l...

Страница 200: ...ave pressed the Accept key a confirmation screen will appear that warns you that the fluid remaining measurement will change as a result of this change Press the Accept key to accept the change and st...

Страница 201: ...om calibration is necessary for non rectangular tanks To perform custom calibration of the tank level sender use the Scroll Up or Scroll Down keys to move the highlighted cursor over the Custom Calibr...

Страница 202: ...first calibration step Enter the first calibration point with an empty tank 0 0 Gallons liters by pressing the Accept key The Current Point highlight will advance to the next point Figure 209 Empty L...

Страница 203: ...will also adjust the tank capacity to the currently indicated level Figure 211 below shows the calibration screen at the last point with the full tank level and thus the tank capacity set to 101 gall...

Страница 204: ...ar tank and you know the capacity of the tank you can easily calibrate the sender by using the Rectangular Tank menu item Figure 213 below shows this option highlighted Use the Scroll Up or Scroll Dow...

Страница 205: ...in the data message This can be set from 0 to 15 6 25 6 Tank Type This is set to the type of fluid in the tank Values are Fuel Fresh Water Waste Water Live Well Oil Black Water Reserved 1 Reserved 7...

Страница 206: ...n Screen 6 28 1 Advanced Configuration Advanced Configuration changes some complex parameters within the device and should only be performed by an advanced user Typically advanced configuration is onl...

Страница 207: ...NMEA2000 PGN Enable Disable menu item selected causes the DSM570 to display the following screen Figure 217 Figure 217 TMP100 NMEA 2000 PGN Enable Disable Screen You can enable or disable the transmis...

Страница 208: ...stem Temperature Inside Temperature Live Well Temperature Main Cabin Temperature Outside Temperature Refrigeration Temperature Sea Temperature User Defined Temperature 129 144 Use this when none of th...

Страница 209: ...Figure 219 USB100 Configuration Screen 6 29 1 Advanced Configuration Advanced Configuration changes some complex parameters within the device and should only be performed by an advanced user Typicall...

Страница 210: ...221 WARNING Do not select multiple devices of the same type for display This will result in multiple and possibly conflicting readings Figure 221 USB100 Device Selection Screen The NA column of the m...

Страница 211: ...pable of performing configuration of the VDR100 Vessel Data Recorder This describes the configuration of the Maretron VDR100 firmware version 2 0 0 4 Figure 222 below shows a screenshot of the VDR100...

Страница 212: ...the VDR100 obtains its LAN connection settings from a DHCP server on the local area network When set to Yes the default value the VDR100 will obtain all necessary connection settings IP Address Subne...

Страница 213: ...r 6 30 8 Default DNS This is the IP address of a computer on the Internet that can identify and locate computer systems and resources on the internet In most cases this should not be required by the V...

Страница 214: ...ltiple pressure sensors on the network 6 31 1 4 Instance Temperature This entry allows you to program the NMEA 2000 device instance for the temperature transmitted in PGN 130312 You usually will not n...

Страница 215: ...e required option using the Scroll Up and Scroll Down keys followed by the Enter key Notice that by default the old Environmental Parameters message PGN 130310 is disabled while the new Environmental...

Страница 216: ...ct to the factory preset can be easily compensated for using the Installation Offset calibration menu item To perform installation offset calibration use the Scroll Up or Scroll Down keys to move the...

Страница 217: ...If the wind speed is sufficient then a confirmation screen shown in Figure 230 below will appear indicating that a successful installation offset calibration has completed Figure 230 Installation Offs...

Страница 218: ...item then press the Enter key to move the highlight to the numerical value on the right This is shown in Figure 232 below Use the Increase and Decrease keys to adjust the damping period to the desired...

Страница 219: ...the current humidity level may be entered in this screen to re calibrate the WSO100 should this be required Figure 234 Setting the Outside Humidity Use the Increase and Decrease buttons to select the...

Страница 220: ...SM570 User s Manual Page 204 Revision 1 8 3 Figure 235 Setting the Outside Temperature Use the Increase and Decrease buttons to select the correct temperature and the press the Enter button to store i...

Страница 221: ...set the Anchor Drop position using the display create a screen with an Anchor Watch display In normal operating mode use the Scroll Up and Scroll Down keys to change to the screen containing the Ancho...

Страница 222: ...in Figure 237 below Figure 237 Bar Graph Display Example 7 3 Compass Rose Display The compass rose display shows a heading bearing or course parameter on a compass rose display There are two types of...

Страница 223: ...Revision 1 8 3 Page 207 Figure 239 Compass Rose North Up Display...

Страница 224: ...ure 240 Date Display Example 7 5 Date Time The Date Time display shows a date and time on a single display The format of the date shown can be set using the Units menu please refer to 5 2 7 13 for det...

Страница 225: ...here is a general gauge format for most types of display and a specialized rudder gauge display A full screen example of a tachometer display can be seen in Figure 242 below Figure 242 Gauge Display E...

Страница 226: ...ut the selected GPS receiver GPS operating mode 2D 3D DGPS Satellite signal strength up to 12 satellites Satellite azimuth and elevation up to 12 satellites Position HDOP Time Date Accuracy of positio...

Страница 227: ...k with an indicator light display that emulates a status light on a control panel The display may be set up in several different configurations Single Indicator Light this creates a single indicator l...

Страница 228: ...se the 4 rows or 2 rows 2 columns indicator light configurations In order to configure the individual indicator lights press the Enter key with the selected type highlighted to display a menu with ent...

Страница 229: ...he default color is red Instance the instance number of the switch bank containing the indicator to be monitored Channel the channel number of the indicator to be monitored Title Sets the text string...

Страница 230: ...on 1 8 3 Figure 249 Numeric Display Example The upper left hand corner indicates the parameter being displayed and the center of the screen shows the numeric value for the indicated parameter The bott...

Страница 231: ...parameter The bottom right hand corner shows the units 7 12Rolling Road The DSM570 supports a Rolling Road or navigation highway display This display repeats transmitted navigation data from a primary...

Страница 232: ...en selected are COG SOG ETA and TTG On the navigation highway itself the waypoint name if available is displayed on the upper left and the waypoint number if available is displayed on the upper right...

Страница 233: ...ne graph display can show the selected data over a time period of 1 2 3 4 5 6 or 7 days Line graph displays are supported only for barometric pressure Figure 253 Line Graph Display 7 14SMS Status The...

Страница 234: ...display shows a time value in an hours and minutes format Figure 255 below shows an example of this type of display Figure 255 Time hh mm Display 7 16Time hh mm ss The Time hh mm ss display shows a ti...

Страница 235: ...rding Please refer to the VDR100 User s Manual for other status that could be displayed on the VDR Status display Figure 257 below shows an example of this type of display Figure 257 VDR Status Displa...

Страница 236: ...lay The weather display shows the following information Wind Direction Ground Referenced Wind Speed Ground Referenced Heat Index Wind Chill Outside Temperature Outside Humidity Barometric Pressure Ins...

Страница 237: ...s in Figure 259 below Figure 259 Wind Rose Display 7 20Moon Phase Display The DSM570 supports a moon phase display which shows the current phase of the moon at the current location An example screensh...

Страница 238: ...on a dual bar graph A screenshot of the trim tab display appears in Figure 262 below Figure 262 Trim Tab Display 7 23Swing Meter Display The DSM570 supports a swing meter display similar to those foun...

Страница 239: ...ith 180 of travel A screenshot of a tank gauge display showing a fuel tank s level appears in Figure 264 below Figure 264 Tank Gauge Display 7 25Watermaker Status The DSM570 supports a watermaker stat...

Страница 240: ...he display may be set up in several different configurations Single Indicator Light this creates a single switch breaker 2 rows this creates four rows of single switches breakers 3 rows this creates t...

Страница 241: ...267 below Figure 267 Selection of an Individual Switch Breaker Figure 268 below shows the configuration menu for each individual switch breaker Figure 268 Configuration of an Individual Switch Breake...

Страница 242: ...h a switch breaker which has been configured to refer to the switch bank instance and indicator number of the switch breaker you want to control In normal operating mode use the Scroll Up and Scroll D...

Страница 243: ...Revision 1 8 3 Page 227 Figure 269 Favorite Screen Showing Highlighted Switch Breaker...

Страница 244: ...mand Message is sent back to the Alert Source 8 1 Displaying Active Alerts Active Alerts are overlaid on all the favorite screens Figure 270 Alert Display The number of Alerts with pending operator ac...

Страница 245: ...ighest priority that requires accepting or cancelling is shown at the bottom left of the screen see Figure 270 This Alert may easily be accepted or cancelled without changing screens by pressing the P...

Страница 246: ...will Accept or Cancel the Alert 8 3 Adding an Alert Alerts are created by selecting the parameter to be monitored e g Depth and then selecting the type of Alert e g High Alert Start by going to the A...

Страница 247: ...n buttons 8 3 2 Alert Type This allows the selection of the type of Alert see paragraph 4 3 1 The options here are Alarm Warning The desired option is selected using the Scroll Up and Scroll Down butt...

Страница 248: ...ttons 8 3 5 Description This is a textual field that will be displayed on the DSM570 and transmitted to Alert Slave devices It is intended to describe the alert e g Fire 8 3 6 Location This is a textu...

Страница 249: ...temporary transitions of the input signal above the High Alert Set Point lasting less than 5 seconds from triggering an alert Once the alert is triggered it becomes an active alert An alert remains a...

Страница 250: ...is field in order for an alert to become active This can be used to prevent false alerts caused by parameter values that briefly have a value that would cause an alert but quickly return to the normal...

Страница 251: ...elay to 5 seconds will eliminate any temporary transitions of the input signal above the Low Alert Set Point lasting less than 5 seconds from triggering an alert Once the alert is triggered it becomes...

Страница 252: ...arameter being monitored must rise above the Low Alert Clear Point value for longer than the time in this field in order for the alert to become inactive The value is entered as minutes seconds If onl...

Страница 253: ...lid value for longer than the time in this field in order for the alert to become inactive 8 3 7 4 Trigger Type is On Alert As opposed to high and low alerts that are associated with analog input sign...

Страница 254: ...at a time the alert will be triggered Alert Clear Delay The condition for the parameter being monitored must be not in its error condition for at least the clear delay time before the alert will becom...

Страница 255: ...0 00 is entered then the alert will never re trigger Alert Set Delay If the switch being monitored is in the Off state for the amount of time specified in this field the alert will become active Alert...

Страница 256: ...is in a state other than Tripped for the amount of time specified in this field the alert will become inactive 8 3 7 7 Trigger Type is Outside Radius Alert The Outside Radius Alert is used to signal a...

Страница 257: ...will begin sounding again for that alert If a value of 0 00 is entered then the alert will never re trigger Alert Set Point If the distance between the current GPS position and the reference position...

Страница 258: ...ated if the vessel comes within a certain distance or radius of a reference point expressed as a longitude and latitude Figure 286 shows an Inside Radius Alert and associated parameters 8 3 7 8 1 Trig...

Страница 259: ...ful when the vessel is anchored or moored and the vessel should not drift outside a perimeter and if it does an alert is activated The point of reference can be selected from the current position or i...

Страница 260: ...field for longer than the time specified in the Alert Set Delay field the alert will become active Alert Clear Point The Alert will be cleared when the quality of the GPS fix as reported by the GPS be...

Страница 261: ...sounding If the condition which caused the alert remains true after the amount of time in this field the alert will return to the Active state and annunciators will begin sounding again for that alert...

Страница 262: ...tive periodically making them useful for signaling watch changes for example every four hours or as a personnel alarm making sure a crew member is at the helm every 15 minutes When a Time Alert with a...

Страница 263: ...econd on one tenth second off beeps followed by one and a half seconds of silence The sequence is repeated This corresponds to the requirements for Temporal 4 alarms T4 CO Fire This is a series of thr...

Страница 264: ...ou may choose to send a message when the alert is triggered when the alert is cleared or both when the alert is triggered and when the alert is cleared After you select this entry and press Enter the...

Страница 265: ...roll Up and Scroll Down buttons and then pressing the Enter button again 8 3 13 Operating Mode Underway See Section 4 3 4 for a description of Operating Modes For this Alert to be triggered when the v...

Страница 266: ...Down buttons and then pressing the Enter button again 8 4 Deleting an Alert From the Alert Setup Menu select the menu item Delete Alert Figure 294 Deleting an Alert This brings up the list of Alerts m...

Страница 267: ...296 Deleting an Alert Confirmation Press the Accept button to delete the Alert or the Cancel button to return to the previous screen without deleting the Alert 8 5 Editing an Alert From the Alert Setu...

Страница 268: ...d with the parameters of the chosen Alert See Section 8 1 for details of these parameters 8 6 Setting the Vessel Operating Mode The Vessel Operating Mode must be set on each DSM570 This is a potential...

Страница 269: ...cted 8 7 SMS Text Phone Book The display is able to transmit SMS text messages via a Maretron SMS100 SMS Text Module in the event of an alert This menu allows you to program up to eight different phon...

Страница 270: ...hange to display the SMS Text Phone Book as shown in the figure below Figure 301 SMS Text Phone Book Screen To edit a number in the phone book press Scroll Up and Scroll Down until the desired entry i...

Страница 271: ...number and saved it by pressing Enter a second time after the last digit is entered you will then be given the chance to edit the name for the phone number as shown in Figure 303 below The purpose of...

Страница 272: ...Phone Book screen Once you have created all of the phone book entries you need press the Back key to exit the SMS Text Phone Book screen 8 8 Advanced Configuration The Advanced Parameters of the Alert...

Страница 273: ...are Enable Disable 8 8 2 Flashing Screen As an extra means to gain the operator s attention to an Active Alert the DSM570 may be set up to flash the entire screen between Red for Alarms or Yellow for...

Страница 274: ...use chemical cleaners as they may remove paint or markings or may corrode the DSM570 enclosure or seals Do not use any cleaners containing acetone as they will deteriorate the plastic enclosure Ensur...

Страница 275: ...ork is in transmitting a valid data value Data fluctuates between two different values Two devices on the network are transmitting the same data Check the Instance Numbers on all devices transmitting...

Страница 276: ...e L L Voltage Phase A Frequency Phase A L N Voltage Phase AB L L Voltage Phase B Frequency Phase B L N Voltage Phase BC L L Voltage Phase C Frequency Phase C L N Voltage Phase CA L L Voltage Anchor Wa...

Страница 277: ...peed Through Water Over Ground Total Log Trip Log Tanks Capacity Level Remaining Temperature Bait Well Battery Engine Coolant Engine Oil Engine Room Exhaust Gas Freezer Heat Index Heating System Insid...

Страница 278: ...e Power N A 65020 Gen Phase C AC Power N A 65021 Gen Phase C AC Basic Quantities N A 65022 Gen Phase B AC Reactive Power N A 65023 Gen Phase B AC Power N A 65024 Gen Phase B AC Basic Quantities N A 65...

Страница 279: ...A 130306 Wind Data N A 130310 Environmental Parameters N A 130311 Environmental Parameters N A 130312 Temperature N A 130313 Humidity N A 130314 Actual Pressure N A 130316 Temperature Extended Range...

Страница 280: ...Flush Mount Environmental Parameter Value IEC 60945 Classification Exposed Degree of Protection IP67 Operating Temperature 20 C to 70 C Storage Temperature 30 C to 80 C Relative Humidity 93 RH 40 C p...

Страница 281: ...ron products you can reach us in any of the following ways Telephone 1 866 550 9100 Fax 1 602 861 1777 E mail support maretron com World Wide Web http www maretron com Mail Carling Technologies Inc At...

Страница 282: ...allation Template Please check the dimensions before using the following diagram as a template for drilling the mounting holes because the printing process may have distorted the template Figure 307 F...

Страница 283: ...PATED PROFITS OR SAVINGS OR ANY OTHER LOSS INCURRED BECAUSE OF INTERRUPTION OF SERVICE IN NO EVENT SHALL CARLING S AGGREGATE LIABILITY EXCEED THE PURCHASE PRICE OF THE PRODUCT S INVOLVED CARLING SHALL...

Отзывы: