Revision 1.8.3
Page 55
6.2 Bennett EP-30 (NMEA1) Trim Tabs Configuration
This describes the configuration of the Bennett EP-
30 trim tabs firmware version 1.0.7 (“NMEA1”
NMEA 2000 Trim Tab Indicator Kit). The EP-30 configuration menu is shown below in Figure 36
below, and currently has the single entry “Trim Tabs Calibration…”.
Figure 36
– EP-30 Trim Tabs Configuration Screen
6.2.1 Trim Tabs Calibration
The Bennett EP-30 (NMEA1) trim tabs calibration opening screen is shown in Figure 37 below. The
first step in calibration is to move both trim tabs to the full up position, and then press the Accept (
) key to begin the calibration process. You may also elect to abort the calibration process at this time
by pressing the Abort (
) key.
Figure 37
– EP-30 Trim Tabs Calibration Opening Screen