A
B
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
F
ACT
OR
Y
DEF
AUL
T
0
0
#
#
1
1
0
0
1
1
0
0
0
#
1 D
0
1
0
SET DETECTORS CODE
SET REMOTE CONTROL CODE
SELF LEARNING OF REMOTE CONTROL AND DETECTORS CODE.
INSTALLER CODE
REG. NO.
4 - the decimal equivalent of the stored code will be
displayed one digit at the time. Enter to exit
PROGRAMMING THE DETECTOR AND REMOTE CONTROL CODES
Following is the procedure to program the Detectors and Remote Controls to operate properly with the MINI-TRACER:
1- program the sensors / detectors following the instructions supplied with each device keeping THE SAME code for all detectors.
2- program the ZONE number ( function) according to your requirements (table 1- page6)
3- enter the self learning mode in the MINI-TRACER by entering:
4- activate any of the programmed DETECTORS making sure that the MINI-TRACER displays the received code
5- press to store/learn the DETECTOR’s code
6- Re-enter the self learning mode in the MINI-TRACER by entering:
7- press any button on the REMOTE CONTROL until the MINI-TRACER displays the different code received.
5- press to store / learn the REMOTE CONTROL code.
Using the same method a 3rd code may be stored using the key to define the code used by an Armed Response
officer to send a “standing” signal to base. Please note that this code cannot be entered manually ( only by self-learn)
A
0
#
1 D
0
1
0
B
MANUALLY PROGRAMMING THE REMOTE CONTROL AND DETECTORS CODE.
1 - Enter the manual setting mode by entering: for the Detectors code
or: for the Remote Control code
2 - set the desired code by toggling each bit of the code using keys 1 to #
(see TABLE)
3 - press and buttons together to store the code and exit .
A
0
#
1
0
1
0
B
0
#
1
0
1
0
#
*
New!!
C
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 0 A B C D * #
KEY
BIT NO
The new MINI-TRACER introduces a new Code structure
which has many advantages to the old 10 bit code. These features are:
- 16 BITS = 65,535 CODE COMBINATIONS.
- multiple PARITY and CHECKSUM = each segment of the code has CHECK SUM and PARITY.
which results in: - wider scope and applications , less duplicate codes and very reliable operation.
known as “SMART CODE”
New!!
1
2
3
4
5
6
ARM
WARN
PER
- 7 -
-4-
(Please note: Both the “Wireless Zone supervision” option (Pg 8) and the active wireless zones (pg 10)
need to be enabled by the installer before this function will work correctly.)
The MINI-TRACER
is capable of reporting a faulty wireless detector.
To display the faulty (non reporting) wireless detector press and hold the key until it beeps
WIRELESS ZONE SUPERVISION
*
An
“ F “ is shown on the display
.
HOLD
TILL BEEP
New!!
1
2
3
4
5
6
ARM
WARN
PER
Faulty detector shown on the ARM Leds
*
WIRELESS ZONE SUPERVISION TEST
ALTHOUGH THE "FACTORY" OPTIONS REFLECT THE CHOICE OF THE MAJORITY OF
INSTALLERS AND END-USERS, PROPER OPERATION AND COMPLIANCE WITH SPECIFIC
REQUIREMENTS CAN BE ACHIEVED THROUGH REPROGRAMMING.
THE PROGRAMMABLE OPTIONS ARE DIVIDED INTO 4 SECTIONS:
- 1 - ENCODING THE WIRELESS DETECTORS AND REMOTE CONTROLS
- 2 - SYSTEM OPTION REGISTERS.
- 3 - SYSTEM I.D. CODES AND TEL. NUMBERS
- 4 - CIRCUIT (ZONE) OPTION REGISTERS.
- 5 - KEYPAD LOCAL OPTION REGISTERS.
SECTIONS 1, 2, 3 AND 4 RELATE TO THE MAIN BOARD:
SECTION 4 IS RELATES TO THE KEYPAD UNIT ITSELF.
FACTORY DEFAULT
"INSTALLER CODE"
=
1
0
0
0
THE TRACER IS ORIGINALLY PROGRAMMED WITH A "FACTORY DEFAULT" SET OF OPTIONS.
INSTALLER PROGRAMMING THE MINI-TRACER
9
0
A
B C D
#
9
0
A
B C D
#
*
*
#
M000037
Содержание Mini TRACER
Страница 1: ...Mini TRACER MAMI MANUFACTURING AND MINOR INVENTIONS Prelim inary issue M000037...
Страница 18: ...Notes M000037...
Страница 19: ...MAMI MANUFACTURING AND MINOR INVENTIONS M000037...