background image

A

B

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

F

ACT

OR

Y

 DEF

AUL

T

0

0

#

#

1

1

0

0

1

1

0

0

0

#

1 D

0

1

0

SET DETECTORS CODE

SET REMOTE CONTROL  CODE

SELF LEARNING OF  REMOTE  CONTROL AND DETECTORS CODE.

INSTALLER CODE

REG. NO.

4 - the decimal equivalent  of  the  stored  code will be
     displayed  one digit at the time. Enter          to exit

PROGRAMMING THE DETECTOR  AND REMOTE CONTROL CODES

Following is the procedure to program the Detectors and Remote Controls  to operate properly with the MINI-TRACER:

1- program the sensors / detectors following the instructions supplied with each device keeping THE SAME code for all detectors.
2- program the ZONE number ( function)  according to your requirements (table 1- page6)
3- enter the self learning mode in the MINI-TRACER by entering:

4- activate any of the programmed DETECTORS making sure that the MINI-TRACER  displays  the received code

5- press         to store/learn  the  DETECTOR’s code

6- Re-enter the self learning mode in the MINI-TRACER by entering:

7- press any button on the REMOTE CONTROL until the MINI-TRACER displays the different  code received.

5- press         to store / learn  the  REMOTE CONTROL code.

Using the same method  a 3rd code may be stored using the         key to define the code used by an Armed Response
officer to  send a “standing” signal to base. Please note  that this code cannot be entered manually ( only by self-learn)

A

0

#

1 D

0

1

0

B

MANUALLY PROGRAMMING  THE   REMOTE  CONTROL  AND  DETECTORS CODE.

1 - Enter the manual setting mode by entering:                                               for the Detectors code
      or:                                                                                                             for the Remote Control code

2 - set the desired code by toggling each bit of the code  using keys 1 to #
 (see TABLE) 

3 - press          and         buttons together to store the code and exit .

A

0

#

1

0

1

0

B

0

#

1

0

1

0

#

*

New!!

C

1   2    3    4    5    6    7    8    9   10  11  12  13  14  15  16

1    2    3    4    5    6    7    8    9    0    A    B    C    D    *    #   

KEY

BIT NO

The new MINI-TRACER introduces a new Code structure 
  which has  many advantages to  the old 10 bit code. These features are: 
- 16  BITS                                               =  65,535  CODE COMBINATIONS.
- multiple PARITY and CHECKSUM      =  each segment of the code has  CHECK SUM and  PARITY.
which results in: - wider scope and applications , less duplicate codes and very reliable operation.

  

                  

known as “SMART CODE” 

New!!

1

2

3

4

5

6

ARM

WARN

PER

- 7 -

-4-

(Please note: Both the “Wireless Zone supervision” option (Pg 8)  and the active wireless zones (pg 10)
need to be enabled by the installer before this function will  work correctly.)

  The MINI-TRACER

 

is capable of reporting a faulty wireless detector. 

 To display the faulty (non reporting) wireless detector press and hold the        key until it beeps 
 

WIRELESS ZONE SUPERVISION

*

 

An 

 

“ F “ is shown on the display

.

HOLD

TILL BEEP

New!!

1

2

3

4

5

6

ARM

WARN

PER

Faulty detector shown on the ARM Leds

*

 WIRELESS ZONE SUPERVISION  TEST

ALTHOUGH   THE  "FACTORY"   OPTIONS   REFLECT   THE   CHOICE  OF  THE   MAJORITY   OF 
  INSTALLERS  AND   END-USERS,   PROPER  OPERATION  AND   COMPLIANCE   WITH   SPECIFIC 
REQUIREMENTS  CAN   BE ACHIEVED  THROUGH  REPROGRAMMING.
THE PROGRAMMABLE OPTIONS ARE DIVIDED INTO  4  SECTIONS:

- 1 - ENCODING THE WIRELESS DETECTORS AND REMOTE CONTROLS
- 2 - SYSTEM OPTION  REGISTERS.
- 3 - SYSTEM  I.D.  CODES  AND  TEL. NUMBERS
- 4 - CIRCUIT (ZONE) OPTION REGISTERS.
- 5 - KEYPAD LOCAL OPTION REGISTERS.

SECTIONS 1, 2, 3  AND 4  RELATE TO THE MAIN BOARD:
SECTION  4  IS  RELATES TO THE KEYPAD  UNIT ITSELF.

FACTORY DEFAULT 
"INSTALLER CODE"
    =  

1

 

0

 

0

 

0

 

THE TRACER  IS   ORIGINALLY  PROGRAMMED  WITH  A  "FACTORY   DEFAULT"  SET  OF  OPTIONS.

INSTALLER PROGRAMMING THE MINI-TRACER

9

0

A

B C D

#

9

0

A

B C D

#

*

*

#

M000037 

Содержание Mini TRACER

Страница 1: ...Mini TRACER MAMI MANUFACTURING AND MINOR INVENTIONS Prelim inary issue M000037...

Страница 2: ...RVISION TEST 10 SECTIONAL PERIMETER INTRUSION SPI SYSTEM 11 PRESET PATTERNS A B C AND D 11 SENSITIVITY 11 ARMING 11 EVENT MEMORY LOGGING DISPLAYING 11 INSTALLER KEYPAD PROGRAMMING S ETTING INDIVIDUAL...

Страница 3: ...c EEPROM memory for retention of both options and code selections during power down Optional wired panic button Optional input for key switch operation Programmable silent PANIC alarm Programmable rep...

Страница 4: ...levels each containing a set of zones which you will most likely select in everyday operation You do not have to remember which set you normally arm or set to warning mode The MINI TRACER will memori...

Страница 5: ...an alarm is achieved in the following manner The system will transmit via radio 3 times at random intervals within 25 seconds NOTE After each Radio transmission the system is dormant for 12 seconds to...

Страница 6: ...lease note that the wireless passive must be enabled for supervision pages 8 10 and See also the wireless detector instructions 8 EVENT MEMORY LOG FACILITY The MINI TRACER Combo is capable of storing...

Страница 7: ...protection device which will blow the safety fuse It may therefore be necessary to change the BATTERY and OUTPUT fuses after connecting the battery incorrectly The unit is NOT GUARANTEED for damages...

Страница 8: ...s two exclusive I D Codes a DETECTOR CODE for sensors and detectors and a REMOTE CONTROL CODE for the hand held remote controls an optional 3rd CODE RESPONSE may be used to indicate to the control roo...

Страница 9: ...see TABLE 3 press and buttons together to store the code and exit A 0 1 0 1 0 B 0 1 0 1 0 New C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 0 A B C D KEY BIT NO The new MINI TRACER intro...

Страница 10: ...ON ON USE KS INPUT WITH A KEY SWITCH OFF TRACER OPERATION ON SNIPER OPERATION OFF NO CONFIRMATION REPEATED OFF SPARE OFF NO REPORT OFF AUTO ARM TIME 15 MINUTES ON ARM DISARM CONFIRMATION REPEATED ON S...

Страница 11: ...SMART USE ALL KEYS 1 9 2 3 4 5 6 7 8 TO EXIT PRESS AND HOLD AND THE DECIMAL VALUE OF THE CODE WILL BE SHOWN ON THE DISPLAY Note that code C cannot be entered manually but only through the self learnig...

Страница 12: ...TCH OFF ENTER TO EXIT ENTER 2 LED 2 WILL TURN OFF ENTER 3 LED 3 WILL TURN ON CHECK THAT THIS IS CORRECT ENTER TO EXIT REGISTER NAME INSTALLER CODE REG NO CIRCUIT ZONE OPTION REGISTERS 10 OFF ec ON 15...

Страница 13: ...2 6 0 1 0 Four preset perimeter selections may be pre programmed to coincide with the arm warn levels A B C D This is done as shown below If option 6 of register 01 page8 is set a selection will be a...

Страница 14: ...GISTER NAME INSTALLER CODE REG NO ON UNUSED OFF NOTE 0 9 0 1 0 ERASE KEYBOARD MEMORY HOLD TILL BEEP NOTE THIS OPERATION WILL ERASE ALL PRESENT VALUES AND RESTORE THE FACTORY DEFAULT VALUES INCLUDING K...

Страница 15: ...N RELAY BATTERY FUSE RX 6 5 4 3 2 1 SIREN BUZZ KS B A K P AC 16V BAT Uhf antennae BEAMS BEAMS NO SW LIT BUZ 8 7 6 5 4 3 2 1 TX RX A B SDA SCK LEARN 8 7 6 5 4 3 2 1 LED S TRANSMITTER NOTE 3 REFER TO SP...

Страница 16: ...TARY N O KEY SWITCH _ 14 Figure 2 12V SUPPLY TO THE DETECTOR MINI TRACER CONNECTIONS 2 KEY SWITCH CONNECTIONS M000037 SIREN RELAY BATTERY FUSE AC B A K P 6 5 4 3 2 1 SIREN BUZZ 17V BAT RX KS NORMALLY...

Страница 17: ...RD 1111 4 PASSWORD USER 4 PASSWORD 1111 5 PASSWORD USER 5 PASSWORD 1111 6 PASSWORD USER 6 PASSWORD 1111 7 PASSWORD USER 7 PASSWORD 1111 8 PASSWORD USER 8 PASSWORD 1111 9 PASSWORD USER 9 PASSWORD 1111...

Страница 18: ...Notes M000037...

Страница 19: ...MAMI MANUFACTURING AND MINOR INVENTIONS M000037...

Отзывы: