The Key Pad  is used to  do the following:

-  program the system's options.
-  access the  4  preset  patterns and if necessary change them.
-  access each zone individually. 
-  change the user codes  ( 10 different user codes per key pad ).
-  activate a  panic alarm .
-  activate a test signal.
-  reset the system /alarm .
-  Quick-setting  one of  four preset levels: “A , B , C or D” to  ALARM  or  WARNING
-  to activate / deactivate the perimeter Sectors.
-  to send a panic signal 
 Combination of 2 keys pressed simultaneously will give different conditions, these are shown in  

Appendix “A”:

NOTE:
       

When arming the system if any of the zones are in open condition the system will sound the key pad bleeper 

      6 times before initializing the arming sequence.
      During the arming sequence it is possible to cancel the operation by pressing ’ 

0

 ' or shorten the delay by pressing ‘

1

’.

      To stop the keypad beeping during a Mains Failure, push and hold the ‘0’.

Most  COMMANDS

  

are  performed  through a 2 CHANNEL HAND-HELD REMOTE CONTROL:

      -  arming and disarming of the system          -  partial arming selection
      -  partial "warning only" selection                  -  programming of the 4 different patterns of arming
      -  panic button                                               -  test transmission
      -  security lights

REPORTING OF AN ALARM  TO A CONTROL ROOM

  

Reporting of an alarm is achieved in the following manner:

  

  

 The system will transmit , via radio,  3 times at random  intervals within 25 seconds

      

NOTE:

 

After each Radio  transmission  the system is dormant for  12 seconds to allow

 

 all

 

 detectors to

 

 

    settle down.

  

During this period the “running” LED on the key board will flash. 

 

1- 

 

STAND-ALONE OPERATION (No Key Pad) - “SNIPER”

      SNIPER operation can be set where 

a single Arm / Disarm level operation is needed. (Register 08 / bit 2 

)

      The remote control (All users) will arm only 

“level A”

 instantly

  

      The Keypad can be removed after programming, leaving only remote control and/or Key-switch for Arming /Disarming.

2- 

 

ARM / DISARM CONFIRMATION

 

     Re- transmission (confirmation) of Arming and Disarming signals can be selected (register 08 / bit 3, ON to Enable) 
     This is meant for business installations where the monitoring of arming status is crucial.
     The  arming status is sent again,  randomly between 30 to 60 minutes, after it was initially Armed or Disarmed. 
     The confirmation is reported to the base-station as a -user 33- Arm/Disarm.
     

3-

    

  

DURESS

     In a life threatening situation.  ( When someone forces you to disarm your alarm panel at  gun-point) you can make the alarm
     panel send a duress to the control room.

4-

  

DURESS ACTIVATION WHEN USING A KEYPAD

     Increment first digit of user code by one (1) when disarming the alarm panel.
     I.e if  ‘ 1 2 3 4 # # ‘ is normally  pressed,    press  ‘2 2 3 4 # # ’ for duress.

EXTRA FUNCTIONS  /  FEATURES:

M000037 

Содержание Mini TRACER

Страница 1: ...Mini TRACER MAMI MANUFACTURING AND MINOR INVENTIONS Prelim inary issue M000037...

Страница 2: ...RVISION TEST 10 SECTIONAL PERIMETER INTRUSION SPI SYSTEM 11 PRESET PATTERNS A B C AND D 11 SENSITIVITY 11 ARMING 11 EVENT MEMORY LOGGING DISPLAYING 11 INSTALLER KEYPAD PROGRAMMING S ETTING INDIVIDUAL...

Страница 3: ...c EEPROM memory for retention of both options and code selections during power down Optional wired panic button Optional input for key switch operation Programmable silent PANIC alarm Programmable rep...

Страница 4: ...levels each containing a set of zones which you will most likely select in everyday operation You do not have to remember which set you normally arm or set to warning mode The MINI TRACER will memori...

Страница 5: ...an alarm is achieved in the following manner The system will transmit via radio 3 times at random intervals within 25 seconds NOTE After each Radio transmission the system is dormant for 12 seconds to...

Страница 6: ...lease note that the wireless passive must be enabled for supervision pages 8 10 and See also the wireless detector instructions 8 EVENT MEMORY LOG FACILITY The MINI TRACER Combo is capable of storing...

Страница 7: ...protection device which will blow the safety fuse It may therefore be necessary to change the BATTERY and OUTPUT fuses after connecting the battery incorrectly The unit is NOT GUARANTEED for damages...

Страница 8: ...s two exclusive I D Codes a DETECTOR CODE for sensors and detectors and a REMOTE CONTROL CODE for the hand held remote controls an optional 3rd CODE RESPONSE may be used to indicate to the control roo...

Страница 9: ...see TABLE 3 press and buttons together to store the code and exit A 0 1 0 1 0 B 0 1 0 1 0 New C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 0 A B C D KEY BIT NO The new MINI TRACER intro...

Страница 10: ...ON ON USE KS INPUT WITH A KEY SWITCH OFF TRACER OPERATION ON SNIPER OPERATION OFF NO CONFIRMATION REPEATED OFF SPARE OFF NO REPORT OFF AUTO ARM TIME 15 MINUTES ON ARM DISARM CONFIRMATION REPEATED ON S...

Страница 11: ...SMART USE ALL KEYS 1 9 2 3 4 5 6 7 8 TO EXIT PRESS AND HOLD AND THE DECIMAL VALUE OF THE CODE WILL BE SHOWN ON THE DISPLAY Note that code C cannot be entered manually but only through the self learnig...

Страница 12: ...TCH OFF ENTER TO EXIT ENTER 2 LED 2 WILL TURN OFF ENTER 3 LED 3 WILL TURN ON CHECK THAT THIS IS CORRECT ENTER TO EXIT REGISTER NAME INSTALLER CODE REG NO CIRCUIT ZONE OPTION REGISTERS 10 OFF ec ON 15...

Страница 13: ...2 6 0 1 0 Four preset perimeter selections may be pre programmed to coincide with the arm warn levels A B C D This is done as shown below If option 6 of register 01 page8 is set a selection will be a...

Страница 14: ...GISTER NAME INSTALLER CODE REG NO ON UNUSED OFF NOTE 0 9 0 1 0 ERASE KEYBOARD MEMORY HOLD TILL BEEP NOTE THIS OPERATION WILL ERASE ALL PRESENT VALUES AND RESTORE THE FACTORY DEFAULT VALUES INCLUDING K...

Страница 15: ...N RELAY BATTERY FUSE RX 6 5 4 3 2 1 SIREN BUZZ KS B A K P AC 16V BAT Uhf antennae BEAMS BEAMS NO SW LIT BUZ 8 7 6 5 4 3 2 1 TX RX A B SDA SCK LEARN 8 7 6 5 4 3 2 1 LED S TRANSMITTER NOTE 3 REFER TO SP...

Страница 16: ...TARY N O KEY SWITCH _ 14 Figure 2 12V SUPPLY TO THE DETECTOR MINI TRACER CONNECTIONS 2 KEY SWITCH CONNECTIONS M000037 SIREN RELAY BATTERY FUSE AC B A K P 6 5 4 3 2 1 SIREN BUZZ 17V BAT RX KS NORMALLY...

Страница 17: ...RD 1111 4 PASSWORD USER 4 PASSWORD 1111 5 PASSWORD USER 5 PASSWORD 1111 6 PASSWORD USER 6 PASSWORD 1111 7 PASSWORD USER 7 PASSWORD 1111 8 PASSWORD USER 8 PASSWORD 1111 9 PASSWORD USER 9 PASSWORD 1111...

Страница 18: ...Notes M000037...

Страница 19: ...MAMI MANUFACTURING AND MINOR INVENTIONS M000037...

Отзывы: