 ZONES

F

ACT

OR

Y

 DEF

AUL

TS

1

2

3

4

5

6

DETECTION TIME

SIREN  ACTIVATION

OPEN / CLOSE  REPORTING

ALARM / RESTORE REPORTING

LEVEL "A"  PRESET

LEVEL "B"  PRESET

LEVEL "C"  PRESET

LEVEL "D"  PRESET

ALWAYS (24Hrs)  ACTIVE ZONE

ACTIVE WirelessL SUPERVISION ZONES

ALARM  REPORTING ZONE

"ENTRY/EXIT DELAY" ZONE

(future expansion)

TO  PROGRAM  EACH  REGISTER:
1-  ENTER  THE  INSTALLER CODE FOLLOWED  BY  THE  CORRESPONDING  REGISTER  NUMBER:  
2- USING  KEYS  "1  to 6”   TOGGLE  THE  CORRESPONDING  LED  (ON=1 OFF=0)

EXAMPLE 1:

- CHANGE  PRESET  LEVEL  "

A

"  FROM  

1

 

&

 

2

   ACTIVE  TO  

1

 

&

 

3

  ACTIVE.

- ENTER: "

1

 

0

 

0

 

0

  

#

 

0

 

A

 ". THE  CURRENT SETTING  WILL  BE  SHOWN.

EXAMPLE 2:

- CHANGE  CIRCUIT  6  NOT  TO  TRIP  THE  SIREN .
- ENTER: " 

1

 

0

 

0

 

0

  

#

 

0

 5  ". THE  CURRENT SETTING

 

   WILL  BE  SHOWN  (ALL  LEDS =  ON).

-  ENTER  " 6 "  ... LED  NO  6  WILL  SWITCH  OFF.
-  ENTER " 

#

 "  TO  EXIT 

- ENTER "

2

" .... LED  2  WILL TURN OFF...

- ENTER "

3

" .... LED  3  WILL TURN ON

- CHECK  THAT  THIS  IS  CORRECT
- ENTER "

#

" TO EXIT 

(REGISTER NAME)

(INSTALLER CODE)

(REG NO.)

 CIRCUIT (ZONE)   OPTION  REGISTERS

-10 -

 

OFF= 

ec.   

ON =

15 Sec.

 0.5 S

Each of the 6 zones can be programmed to behave in different ways and perform
 different tasks. To  do this there are several registers: 

PROGRAMMING (CONTINUED)

1  2  3  4  5  6  7  8

1

2

3

4

5

6

ARM

WARN

PER

AFTER  YOU  HAVE  ENTERED  THE  

INSTALLER  CODE  AND  THE  REGISTER

NUMBER,    USE  KEYS  "1  to 8" TO 

MAKE  YOUR  SELECTION .

ENTER  "#"  TO EXIT

EVENT MEMORY LOG

0

3

0

1

0

ZONES ARMED

ZONES TRIGGERED

LOG NUMBER

DAY

HOUR

MINUTES

SECONDS

TYPE

LIST OF  ALARM TYPES :

0 = Alarm                                 6 = System Mains Fail                  7 = System Battery Low         
8 = System Mains Restore      9 = System Battery Restore         P = Panic 
D = Duress                              T = Test/Cancel                            A = System Armed
d = System Disarmed

{

{

{

{

{

{

1

2

3

4

5

6

USE         TO GO TO PREVIOUS EVENT

USE         TO GO TO THE MORE RECENT EVENT

A

D

     When not reporting to a control room, the user can view 255 events which occurred on the alarm panel. 
     This feature  displays the events and  time between events as follows :

3

#

M000037 

Содержание Mini TRACER

Страница 1: ...Mini TRACER MAMI MANUFACTURING AND MINOR INVENTIONS Prelim inary issue M000037...

Страница 2: ...RVISION TEST 10 SECTIONAL PERIMETER INTRUSION SPI SYSTEM 11 PRESET PATTERNS A B C AND D 11 SENSITIVITY 11 ARMING 11 EVENT MEMORY LOGGING DISPLAYING 11 INSTALLER KEYPAD PROGRAMMING S ETTING INDIVIDUAL...

Страница 3: ...c EEPROM memory for retention of both options and code selections during power down Optional wired panic button Optional input for key switch operation Programmable silent PANIC alarm Programmable rep...

Страница 4: ...levels each containing a set of zones which you will most likely select in everyday operation You do not have to remember which set you normally arm or set to warning mode The MINI TRACER will memori...

Страница 5: ...an alarm is achieved in the following manner The system will transmit via radio 3 times at random intervals within 25 seconds NOTE After each Radio transmission the system is dormant for 12 seconds to...

Страница 6: ...lease note that the wireless passive must be enabled for supervision pages 8 10 and See also the wireless detector instructions 8 EVENT MEMORY LOG FACILITY The MINI TRACER Combo is capable of storing...

Страница 7: ...protection device which will blow the safety fuse It may therefore be necessary to change the BATTERY and OUTPUT fuses after connecting the battery incorrectly The unit is NOT GUARANTEED for damages...

Страница 8: ...s two exclusive I D Codes a DETECTOR CODE for sensors and detectors and a REMOTE CONTROL CODE for the hand held remote controls an optional 3rd CODE RESPONSE may be used to indicate to the control roo...

Страница 9: ...see TABLE 3 press and buttons together to store the code and exit A 0 1 0 1 0 B 0 1 0 1 0 New C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 0 A B C D KEY BIT NO The new MINI TRACER intro...

Страница 10: ...ON ON USE KS INPUT WITH A KEY SWITCH OFF TRACER OPERATION ON SNIPER OPERATION OFF NO CONFIRMATION REPEATED OFF SPARE OFF NO REPORT OFF AUTO ARM TIME 15 MINUTES ON ARM DISARM CONFIRMATION REPEATED ON S...

Страница 11: ...SMART USE ALL KEYS 1 9 2 3 4 5 6 7 8 TO EXIT PRESS AND HOLD AND THE DECIMAL VALUE OF THE CODE WILL BE SHOWN ON THE DISPLAY Note that code C cannot be entered manually but only through the self learnig...

Страница 12: ...TCH OFF ENTER TO EXIT ENTER 2 LED 2 WILL TURN OFF ENTER 3 LED 3 WILL TURN ON CHECK THAT THIS IS CORRECT ENTER TO EXIT REGISTER NAME INSTALLER CODE REG NO CIRCUIT ZONE OPTION REGISTERS 10 OFF ec ON 15...

Страница 13: ...2 6 0 1 0 Four preset perimeter selections may be pre programmed to coincide with the arm warn levels A B C D This is done as shown below If option 6 of register 01 page8 is set a selection will be a...

Страница 14: ...GISTER NAME INSTALLER CODE REG NO ON UNUSED OFF NOTE 0 9 0 1 0 ERASE KEYBOARD MEMORY HOLD TILL BEEP NOTE THIS OPERATION WILL ERASE ALL PRESENT VALUES AND RESTORE THE FACTORY DEFAULT VALUES INCLUDING K...

Страница 15: ...N RELAY BATTERY FUSE RX 6 5 4 3 2 1 SIREN BUZZ KS B A K P AC 16V BAT Uhf antennae BEAMS BEAMS NO SW LIT BUZ 8 7 6 5 4 3 2 1 TX RX A B SDA SCK LEARN 8 7 6 5 4 3 2 1 LED S TRANSMITTER NOTE 3 REFER TO SP...

Страница 16: ...TARY N O KEY SWITCH _ 14 Figure 2 12V SUPPLY TO THE DETECTOR MINI TRACER CONNECTIONS 2 KEY SWITCH CONNECTIONS M000037 SIREN RELAY BATTERY FUSE AC B A K P 6 5 4 3 2 1 SIREN BUZZ 17V BAT RX KS NORMALLY...

Страница 17: ...RD 1111 4 PASSWORD USER 4 PASSWORD 1111 5 PASSWORD USER 5 PASSWORD 1111 6 PASSWORD USER 6 PASSWORD 1111 7 PASSWORD USER 7 PASSWORD 1111 8 PASSWORD USER 8 PASSWORD 1111 9 PASSWORD USER 9 PASSWORD 1111...

Страница 18: ...Notes M000037...

Страница 19: ...MAMI MANUFACTURING AND MINOR INVENTIONS M000037...

Отзывы: